Detailed Discussions of Bit 2
It converts "inch" into "mm" when transmitting the received image data.
Scanning direction in conversion follows the Bit 2 setting of SW14.
● SSSW-SW014
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
direction of scanning for inch/mm conversion
both main and sub scanning di-
rections
sub scanning direction only
3
not used
-
-
4
inch-configuration resolution declaration
declare
do not declare
5
not used
-
-
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 2
Use it to specify whether to convert or not convert an inch-configuration resolution into a millimeter-configuration resolution for
image read in G3 transmission:
either in sub scanning direction only or in both main and sub scanning directions. The setting is valid only when bit 1 of SW05 of
#SSSW is set to '1'.
Detailed Discussions of Bit 4
Use it to specify whether to declare or not declare an inch-configuration resolution to the other machine for G3 communication:
if 'declare' is selected, the machine will indicate that it reads and records at an inch-configuration resolution using the DIS, DCS,
or DTC signal.
● SSSW-SW15
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
Reception of call through caller ID display line
(main unit line)
Yes
No
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
Detection of continuous signal at fax/tel switch-
over
Yes
No
7
not used
-
-
Detailed Discussions of Bit 2
When a machine which is not compatible with the caller ID display/modem dial-in service is connected to the subscriber line which
is compatible with that service, the "main unit line" is made ready for receiving the incoming call.
Detailed Discussions of Bit 6
Select whether to detect a continuous ROT signal at FAX/TEL switchover.
● SSSW-SW18
List of Functions
Bit
Function
1
0
0
detection of carrier between DCS and TCF
detect
do not detect
1
wait time for carrier between DCS and TCF
600msec
300msec
2
To disable communication control for IP network. Yes
No
8. Service Mode
231
Summary of Contents for imageRUNNER 2525 Series
Page 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Page 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Page 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Page 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Page 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Page 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Page 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Page 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Page 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Page 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Page 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Page 314: ...Example of report display 8 Service Mode 304 ...
Page 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...