8.8 Dual Panels for Back-Up Redundancy
The proceeding parts of Section 8, discusses using two panels for two operators. Two panels
may also be used by one operator for redundancy.
Every system comes with a SoftPanel and a physical panel that may be used by one person
for redundancy. If one panel should fail, the other one may be used.
Physical Control Panel and SoftPanels
This capability is standard with every Broadcast Pix Switcher system. If the control panel
should fail, then press
Reconnect
on the SoftPanel’s web browser to connect it. If you wish it
to be always available, you need an optional additional panel license, see section 8.1
Dual Physical Panels
An optional second control panel may be added to any Flint system. The second control panel
needs to have a different IP address than the main control panel. This is accomplished with
changing the Panel IP address on the control panel, in the Panel Setup & Test mode, while
the panel is off line.
The default IP address of a 1ME 2000 panel is: 192.168.53.247
The default IP address of a 1ME 1000 panel is: 192.168.53.251
The default IP address of a 1ME 500 panel is: 192.168.53.246
To change the Panel IP address:
1. Make sure the control is if
Offline
, by closing the BPswitcher application.
2. The 3 wildcard device buttons in the Device Control will illuminate, select the
[Panel Setup + Test] A
button and it will illuminate orange, as shown below.
3.
The PixPad will illuminate, as shown below, select the
[Panel IP]
PixButton. The
PixPad will change to a numeric PixPad.
8.8
Panel
Setup
+ Test
Fail
Safe
Join
the
show
TEST
VFD
TEST
CTRLS
TEST
PIX
SHOW
KNOB
SHOW
BUTS
SHOW
JOYS
SHOW
DATE
PANEL
IP
SET
URL
LIGHT
SHOW
SET
MODE
SET
COLOR