![Broadcast Pix Flint LE 1000 Operator'S Manual Download Page 356](http://html1.mh-extra.com/html/broadcast-pix/flint-le-1000/flint-le-1000_operators-manual_2815459356.webp)
install - concepts - PixMaster - switcher - CG - clips - controls - team - appendix
FLINT
V1.1
Single or Multiple Panasonic IP Configuration:
7.4.1
Straight cat5 cable
Network Hub
Cable Consideration:
When connecting through a hub, a straight cat5 or higher rated STP (shielded
twisted pair) cable is recommended. There is a maximum distance of 100 meters (328
feet).
When connecting directly to the Server, a crossover cat5 or higher rated STP (shielded
twisted pair) cable is recommended. There is a maximum distance of 100 meters (328
feet).
IP & Serial Control of Panasonic Cameras:
In some installations it is desired to have a Panasonic controller for a dedicated operator
and have the Broadcast Pix system used to trigger Macros or to control other cameras.
In this type of installation the IP control would be connected to a Panasonic controller, like
the AW-RP50, and the serial control using the AW-CA20T6G breakout cable would connect
to the Broadcast Pix System.
AW-HE50 Rear LAN port
Broadcast Pix Server LAN port
Broadcast Pix Control Panel
Pin
Function
3
TXD (A) -
7
TXD (B) +
8
RXD (A) -
4
RXD (B) +
5
GND
Pin
Function
6 B
RXD (A) -
6 A
RXD (B) +
10 B
TXD (A) -
10 A
TXD (B)+-
8 A
GND
DB 9-Pin (Edgeort) Centronics/Hirose 20-pin (Panasonic)