334
BinTec Communications AG
Troubleshooting
9
➤
Evaluate the syslog messages (Level =
debug) and, if applicable, filter out
the IPX packets indicated in the messages as causing unwanted connec-
tions to be set up.
The MIB variable ipxAdmSpxConns shows more connections
than are actually active.
X3200
may not be receiving SPX disconnect messages from the server:
➤
Enter the command
reset router
on the console of the respective serv-
er.
All inactive connections between the server and
X3200
are cleared.
➤
If the disconnect for the client is lost, SPX connections could remain until
timeout. These connections would then be displayed in ipxAdmSpxConns
until timeout.