262
BinTec Communications AG
Security Mechanisms
7
Table 7-1:
S
YSTEM
Message Level for
Syslog Table
Specifies the priority of the syslog messages to
be recorded internally. Possible values:
■
emerg: emergency messages (highest pri-
ority)
■
alert: alert messages
■
crit: critical messages
■
err: error messages
■
warning: warning messages
■
notice: notice messages
■
info: info messages
■
debug: debug messages (lowest priority)
Syslog messages are only recorded internally if
they have a higher or identical priority to that
indicated.
Maximum Number of
Syslog Entries
Maximum number of syslog messages saved in
X3200
.
(possible values:
0 - 1000).
Field
Meaning
Log Host
➤➤
IP address
of the host to which syslog
messages are passed.
Level
Priority of the syslog messages to be sent to
Log Host. Corresponds to Message Level for
Syslog Table in
S
YSTEM
.
Facility
Syslog facility at Log Host. Only required if the
Log Host is a Unix computer.
Field
Meaning