YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
681
No.
(Hex.)
Name
Description
MFAO Signal Level
U5-03
(0064)
PID Output
Shows the PID control output as a percentage of the maximum output frequency.
Unit: 0.01%
10 V: Maximum frequency
(0 V to +10 V)
U5-04
(0065)
PID Setpoint
Shows the PID setpoint.
Unit: 0.01%
Note:
Parameters
b5-46 [PID Unit Display Selection]
,
b5-38 [PID User Unit Display Scaling]
, and
b5-
39 [PID User Unit Display Digits]
set the unit, range, and resolution.
10 V = Maximum frequency
(-10 V to +10 V)
U5-05
(07D2)
PID DifferentialFdbk
Shows the PID differential feedback value as a percentage of the maximum output frequency.
This monitor is available after you set
H3-02 or H3-10 = 16 [Terminal A1/A2 Function Selection =
Differential PID Feedback]
.
Unit: 0.01%
10 V = Maximum frequency
(-10 V to +10 V)
U5-06
(07D3)
PID FdbkDif PID Fdbk
Shows the difference from calculating
“
U5-05 [PID DifferentialFdbk] - U5-01[PID Feedback]
”
.
Unit: 0.01%
Note:
U5-01 [PID Feedback]
=
U5-06
when
H3-02 or H3-10 ≠ 16 [Terminal A1/A2 Function Selection
≠ Differential PID Feedback]
.
10 V = Maximum frequency
(-10 V to +10 V)
U5-07
(0072)
AUTO Mode Freq Ref
Shows the Frequency reference value at AUTO Mode.
Unit: 0.01 Hz
Note:
Parameter
o1-03 [Frequency Display Unit Selection]
sets the display unit.
No signal output available
U5-08
(0073)
HAND Mode Freq Ref
Shows the Frequency reference value at HAND Mode.
Unit: 0.01 Hz
Note:
Parameter
o1-03 [Frequency Display Unit Selection]
sets the display unit.
No signal output available
U5-14
(086B)
PID Out2 Upr4 Digits
Shows the custom PI output.
Monitor
U5-14
shows the upper four digits and
U5-15 [PID Out2 Lwr4 Digits]
shows the lower four
digits.
The drive uses
b5-43 [PID Out2 Monitor MAX Upper4 Dig]
and
b5-44 [PID Out2 Monitor MAX
Lower4 Dig]
to scale the monitors.
Unit: 1
Note:
Parameter
b5-41 [PID Output 2 Unit]
sets the display unit.
10 V = b5-43 × 10000
U5-15
(086C)
PID Out2 Lwr4 Digits
Shows the custom PI output.
Monitor
U5-14
shows the upper four digits and
U5-15 [PID Out2 Lwr4 Digits]
shows the lower four
digits.
The drive uses
b5-43 [PID Out2 Monitor MAX Upper4 Dig]
and
b5-44 [PID Out2 Monitor MAX
Lower4 Dig]
to scale the monitors.
Unit: 0.01
Note:
Parameter
b5-41 [PID Output 2 Unit]
sets the display unit.
b5-43 > 0: 10 V = 10000
b5-43 = 0: 10 V = b5-44
U5-16
(086D)
PI Aux Ctrl Feedback
Shows the PI Auxiliary Control Feedback level from the terminal set for
H3-xx = 27 [PI Auxiliary
Control Feedback]
.
Unit: PSI
Note:
Parameters
YF-21 [PI Aux Ctrl Level Unit Selection]
and
YF-22 [PI Aux Level Decimal Place
Pos]
set the unit and resolution.
No signal output available
U5-17
(086E)
PI2 Control Setpoint
Shows the PI2 Control setpoint.
Note:
Parameters
S3-04 [PI2 Control Unit Selection]
and
S3-03 [PI2 Control Decimal Place Pos]
set
the unit and resolution.
10 V = S3-02
U5-18
(086F)
PI2 Control Feedback
Shows the PI2 Control Feedback Level from the terminal set for
H3-xx = 26 [PI2 Control
Feedback]
.
Note:
Parameters
S3-04 [PI2 Control Unit Selection]
and
S3-03 [PI2 Control Decimal Place Pos]
set
the unit and resolution.
10 V = S3-02
U5-19
(0870)
PI2 Control Input
Shows the PI2 Control input (deviation between PI target and feedback).
Note:
Parameters
S3-04 [PI2 Control Unit Selection]
and
S3-03 [PI2 Control Decimal Place Pos]
set
the unit and resolution.
10 V = S3-02
U5-20
(0871)
PI2 Control Output
Shows the PI2 Control output.
Note:
•
Parameters
S3-04 [PI2 Control Unit Selection]
and
S3-03 [PI2 Control Decimal Place Pos]
set
the unit and resolution.
•
The drive operation while
H1-xx = A8 or 1A8 [PI2 Control Disable]
changes when the
S3-12
[PI2 Control Disable Mode Sel]
setting changes.
10 V = S3-02
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...