9.13 o: Keypad-Related Settings
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
643
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
o1-43
(11C3)
RUN
2nd Monitor Area
Selection
Selects the horizontal range used to display the monitor set in
o1-25 [Custom Monitor 2]
as a bar graph. This parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
0
(0 - 1)
o1-44
(11C4)
RUN
2nd Monitor Area Setting Sets the horizontal axis value used to display the monitor set in
o1-25 [Custom Monitor 2]
as a bar graph. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
o1-45
(11C5)
RUN
3rd Monitor Area
Selection
Sets the horizontal range used to display the monitor set in
o1-26 [Custom Monitor 3]
as a
bar graph. This parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
0
(0 - 1)
o1-46
(11C6)
RUN
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-26 [Custom Monitor 3]
as a bar graph. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
o1-47
(11C7)
RUN
Trend Plot 1 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in
o1-24 [Custom
Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
-100.0%
(-300.0 - +300.0%)
o1-48
(11C8)
RUN
Trend Plot 1 Scale
Maximum Value
Sets the horizontal axis maximum value used to display the monitor set in
o1-24 [Custom
Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
100.0%
(-300.0 - +300.0%)
o1-49
(11C9)
RUN
Trend Plot 2 Scale
Minimum Value
Sets the horizontal axis minimum value used to display the monitor set in
o1-25 [Custom
Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
-100.0%
(-300.0 - +300.0%)
o1-50
(11CA)
RUN
Trend Plot 2 Scale
Maximum Value
Sets the horizontal axis maximum value used to display the monitor set in
o1-25 [Custom
Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
100.0%
(-300.0 - +300.0%)
o1-51
(11CB)
RUN
Trend Plot Time Scale
Setting
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting,
the drive automatically adjusts the data sampling time. This parameter is only available on
an HOA keypad.
300 s
(1 - 3600 s)
o1-55
(11EE)
RUN
Analog Gauge Area
Selection
Sets the range used to display the monitor set in
o1-24 [Custom Monitor 1]
as an analog
gauge. This parameter is only available on an HOA keypad.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
1
(0, 1)
o1-56
(11EF)
RUN
Analog Gauge Area
Setting
Sets the value used to display the monitor set in
o1-24 [Custom Monitor 1]
as an analog
meter. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
o1-58
(3125)
Motor Power Unit
Selection
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
1
(0, 1)
o1-80
(31BA)
Fault Screen Display
Sets a full-screen display message to show on the keypad when a fault or CPF occurs.
0 : OFF
1 : ON
1
(0, 1)
o1-81
(31BB)
Alarm Screen Display
Sets a full-screen display message to show on the keypad when an alarm occurs.
0 : OFF
1 : ON
0
(0, 1)
o1-82
(31BC)
Message Screen Display
Sets a full-screen display message to show on the keypad when a status message is active.
0 : OFF
1 : ON
0
(0, 1)
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...