7.10 Peripheral Devices and Options
550
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
A - Shield
B - Sheath
C - Insulate with electrical tape or shrink tubing.
Figure 7.5 Prepare the Ends of Shielded Wire
■
Prepare Network Cables for Non-LonWorks Options
Determine the length of cable required to connect from the option to a network device and attach all connectors to
network cables before you install the option.
The network connection point on the option is designated CN1. CN1 may have 2 ports depending on the option type.
CN1 is the connection point for a customer-supplied network cable with a modular RJ45 connector.
Table 7.25 8-Way Modular Connector (Customer-Supplied)
Male 8-Way Modular Connector
Pin
Description
1 (Pair 2)
Transmit data (TXD) +
2 (Pair 2)
Transmit data (TXD) -
3 (Pair 3)
Receive data (RXD) +
4 (Pair 1)
Not used for 10 Mbps and 100 Mbps networks
5 (Pair 1)
Not used for 10 Mbps and 100 Mbps networks
6 (Pair 3)
Receive data (RXD) -
7 (Pair 4)
Not used for 10 Mbps and 100 Mbps networks
8 (Pair 4)
Not used for 10 Mbps and 100 Mbps networks
Communication Protocol
Description
EtherNet/IP
Only use cable recommended for EtherNet/Industrial Protocol (EtherNet/IP™). Using a cable not specifically recommended may
cause the option or bypass to malfunction. Refer to the ODVA website for more information on network cabling (www.odva.org).
Modbus TCP/IP
Only use cable recommended for Modbus TCP/IP. Using a cable not specifically recommended may cause the option or bypass to
malfunction. Refer to the Modbus-IDA website for more information on network cabling (www.modbus.org).
PROFINET
Only use cable recommended for PROFINET. Using a cable not specifically recommended may cause the option or bypass to
malfunction. Refer to the PROFIBUS and PROFINET International (PI) website for more information (www.profibus.com).
■
Install the Option
1.
Remove the bypass cover.
2.
Put the option into port CN5 on the bypass PCB.
Latch release
1 2 3 4 5 6 7 8
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...