710
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Object ID
Object Name
(
Network Display, if
Different
)
Modbus Reg.
Active Text
Inactive Text
PV Access
BV61
Bypass Transfer to Bypass
Cmd
(
BYP Xfer to BYP CMD
)
8400h: Bit 3
ON
OFF
C
BV62
Emergency Override Bypass
(
Em Over BYPASS CMD
)
8400h: Bit 4
ON
OFF
C
BV63
Emergency Override Drive
Forward
(
Em Over DRV FWD CMD
)
8400h: Bit 5
ON
OFF
C
BV64
Bypass Motor OR Select
Command
(
BYP Mtr OR Sel CMD
)
8400h: Bit 6
ON
OFF
C
BV65
Bypass Motor AND Select
Command
(
BYP Mtr AND Sel CMD
)
8400h: Bit 7
ON
OFF
C
BV66
Not Used BV066
-
ON
OFF
R
BV67
Not Used BV067
-
ON
OFF
R
BV68
Not Used BV068
-
ON
OFF
R
BV69
Bypass BYPASS Select
Command
(
BYP BYPASS Sel CMD
)
8400h: Bit C
ON
OFF
C
BV70
Bypass Fault Reset
Command
(
BYP Fault Reset CMD
)
8400h: Bit D
ON
OFF
C
BV71
Bypass External Fault
Command
(
BYP Ext Fault CMD
)
8400h: Bit E
ON
OFF
C
BV72
Bypass DI-01 Command
(
BYP DI-01 Command
)
8402h: Bit 0
ON
OFF
C
BV73
Bypass DI-02 Command
(
BYP DI-02 Command
)
8402h: Bit 1
ON
OFF
C
BV74
Bypass DI-03 Command
(
BYP DI-03 Command
)
8402h: Bit 2
ON
OFF
C
BV75
Bypass DI-04 Command
(
BYP DI-04 Command
)
8402h: Bit 3
ON
OFF
C
BV76
Bypass DI-05 Command
(
BYP DI-05 Command
)
8402h: Bit 4
ON
OFF
C
BV77
Bypass DI-06 Command
(
BYP DI-06 Command
)
8402h: Bit 5
ON
OFF
C
BV78
Bypass DI-07 Command
(
BYP DI-07 Command
)
8402h: Bit 6
ON
OFF
C
BV79
Bypass DI-08 Command
(
BYP DI-08 Command
)
8402h: Bit 7
ON
OFF
C
BV80
Bypass HAND Mode Status
(
BYP HAND Mode Status
)
8784h: Bit 0
ON
OFF
R
BV81
Bypass OFF Mode Status
(
BYP OFF Mode Status
)
8784h: Bit 1
ON
OFF
R
BV82
Bypass AUTO Mode Status
(
BYP AUTO Mode Status
)
8784h: Bit 2
ON
OFF
R
BV83
Bypass DRIVE Mode Status
(
BYP DRV Mode Status
)
8784h: Bit 3
ON
OFF
R
BV84
Bypass BYPASS Mode
Status
(
BYP BYPASS Mode Stat
)
8784h: Bit 4
ON
OFF
R
BV85
Bypass Emergency Run
Bypass Status
(
BYP Smk Prg BYP Stat
)
8784h: Bit 5
ON
OFF
R
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...