8.5 Replace the Keypad Battery
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
587
8.5
Replace the Keypad Battery
When the keypad battery is expired, the date and time go back to the default settings. Use this procedure to replace
the battery.
WARNING!
Fire Hazard. Handle keypad batteries properly. Do not charge the battery or disassemble the keypad. If the battery
explodes, it can cause a fire.
To replace the battery, use a Hitachi Maxell
“
CR2016 Lithium Manganese Dioxide Lithium Battery
”
or an equivalent
battery with these properties:
•
Nominal voltage: 3 V
•
Operating temperature range: -20 °C to + 85°C (-4 °F to +185 °F)
WARNING!
Fire Hazard. Do not disassemble batteries. Do not expose batteries to heat or fire. If the battery explodes, it can cause a
fire.
NOTICE:
Damage to Equipment. The keypad battery stays in use after you de-energize the bypass. When you will keep the bypass
de-energized for long periods of time, remove the battery from the keypad. When the expected life of the battery is complete,
replace the battery immediately. A dead battery in the keypad can leak and cause damage to the keypad and bypass.
The performance life estimate of a new battery is:
•
Ambient temperature 20 °C (68 °F): 5 years
•
Ambient temperature -10 °C to +50 °C (14 °F to 122 °F): 3.5 years
1.
De-energize the drive and remove the keypad.
2.
Use a slotted screwdriver or other tool to turn the battery cover counterclockwise and remove the cover.
A - Battery cover
B - Opened
C - Closed
Figure 8.61 Remove the Battery Cover
3.
Remove the used battery from the keypad.
4.
Insert the new battery.
Note:
• The battery cover side is the positive pole. Make sure that the polarity is correct when you put the battery in the keypad.
• Discard the used battery as specified by local regulations.
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...