6.3 Faults, Minor Faults, Alarms, and Error Codes Listed Alphabetically
464
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Display (Hex.)
Name
ALM LED
Type
Ref.
oH3 (0022)
Motor Overheat (PTC Input)
Flashing
Alarm
oH4 (0020)
Motor Overheat Fault (PTC Input)
Illuminated
Drive Fault
oL1 (000B)
Motor Overload
Illuminated
Drive Fault
oL2 (000C)
Drive Overload
Illuminated
Drive Fault
oL3 (0005)
Overtorque 1
Flashing
Alarm
oL3 (000D)
Overtorque Detection 1
Illuminated
Drive Fault
oL4 (0006)
Overtorque 2
Flashing
Alarm
oL4 (000E)
Overtorque Detection 2
Illuminated
Drive Fault
oL7 (002B)
High Slip Braking Overload
Illuminated
Drive Fault
oPE01
Drive Capacity Setting Fault
Flashing
Parameter Setting Error
oPE02
Parameter Range Setting Error
Flashing
Parameter Setting Error
oPE03
Multi-Function Input Setting Err
Flashing
Parameter Setting Error
oPE05
Run Cmd/Freq Ref Source Sel Err
Flashing
Parameter Setting Error
oPE07
Analog Input Selection Error
Flashing
Parameter Setting Error
oPE08
Parameter Selection Error
Flashing
Parameter Setting Error
oPE09
PID Control Selection Fault
Flashing
Parameter Setting Error
oPE10
V/f Data Setting Error
Flashing
Parameter Setting Error
oPE11
Carrier Frequency Setting Error
Flashing
Parameter Setting Error
oPE16
Energy Saving Constants Error
Flashing
Parameter Setting Error
oPE29
Baud Rate Setting Error
Flashing
Parameter Setting Error
oPE33
Digital Output Selection Error
Flashing
Parameter Setting Error
oPE34
HAND/OFF/AUTO Input Setting
Flashing
Parameter Setting Error
oPE36
Bypass Energy Savings Setting Err
Flashing
Parameter Setting Error
oPr (001E)
Keypad Connection Fault
Illuminated
Drive Fault
ov (0002)
DC Bus Overvoltage
Flashing
Alarm
ov (0008)
Overvoltage
Illuminated
Drive Fault
ov2 (0405)
DC Bus Overvoltage 2
Illuminated
Drive Fault
ovEr
Too Many Parameters Changed
-
Not an alarm.
OV_PRESS (00CD)
Over Pressure Detected
Flashing
Alarm
PASS
Modbus Communication Test
Flashing
Not an alarm.
PE1 (0047)
PE2 (0048)
PLC Faults
Illuminated
Drive Fault
PF (0047)
Input Phase Loss
Flashing
Alarm
PF (001B)
Input Phase Loss
Illuminated
Drive Fault
rdEr
Error Reading Data
-
Backup Function Runtime Error
SAFE (0062)
Customer Safeties
Flashing
Alarm
SAFE (00C9)
Safety Open
Flashing
Alarm
SC (0005)
Short Circuit/IGBT Failure
Illuminated
Drive Fault
SCF (040F)
Safety Circuit Fault
Illuminated
Drive Fault
SE (0020)
Modbus Test Mode Error
Flashing
Alarm
SEr (003B)
Speed Search Retries Exceeded
Illuminated
Drive Fault
SMK_ALRM (00CC)
Smoke Alarm Active
Flashing
Alarm
STo (003C)
Safe Torque OFF
-
Alarm
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...