5.10 o: Keypad-Related Settings
360
YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
0 : Custom Monitor
1 : Bar Graph
2 : Analog Gauge
3 : Trend Plot
■
o1-41: 1st Monitor Area Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-41
(11C1)
RUN
1st Monitor Area Selection
Sets the horizontal range used to display the monitor set in
o1-24 [Custom Monitor 1]
as a bar graph.
This parameter is only available on an HOA keypad.
0
(0 - 1)
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
■
o1-42: 1st Monitor Area Setting
No.
(Hex.)
Name
Description
Default
(Range)
o1-42
(11C2)
RUN
1st Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-24 [Custom Monitor 1]
as a bar
graph. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
■
o1-43: 2nd Monitor Area Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-43
(11C3)
RUN
2nd Monitor Area Selection
Selects the horizontal range used to display the monitor set in
o1-25 [Custom Monitor 2]
as a bar
graph. This parameter is only available on an HOA keypad.
0
(0 - 1)
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
■
o1-44: 2nd Monitor Area Setting
No.
(Hex.)
Name
Description
Default
(Range)
o1-44
(11C4)
RUN
2nd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-25 [Custom Monitor 2]
as a bar
graph. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
■
o1-45: 3rd Monitor Area Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-45
(11C5)
RUN
3rd Monitor Area Selection
Sets the horizontal range used to display the monitor set in
o1-26 [Custom Monitor 3]
as a bar graph.
This parameter is only available on an HOA keypad.
0
(0 - 1)
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
■
o1-46: 3rd Monitor Area Setting
No.
(Hex.)
Name
Description
Default
(Range)
o1-46
(11C6)
RUN
3rd Monitor Area Setting
Sets the horizontal axis value used to display the monitor set in
o1-26 [Custom Monitor 3]
as a bar
graph. This parameter is only available on an HOA keypad.
100.0%
(0.0 - 100.0%)
Содержание HV600
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...