Technical Handbook 69
To use the Global Navigation Satellite System (
GNSS
) internal receiver, using
GPS
,
GLONASS, GALILEO
or
BeiDou
system, the internal module must be enabled with the
parameter
P.0580 (
GPS module enable) set to “
1-YES
”. Connect also the GNSS antenna.
The purpose of this module is to detect the controller position (latitude/longitude). Once detected,
the position coordinates can be asked via
SMS*
and it can be used to pinpoint the genset on a
map (many business sites allow this operation).
The position
becomes most important in the use with “
Si.Mo.Ne.
” system. Directly from the WEB
interface it is possible to display the position of a genset on a map, and it is also possible to
display the tracking of a rented genset in a period of time: both these functions are useful for
rented gensets, but can also be used as antitheft system.
If you use the
GNSS
module, it is possible to configure the controller to send messages to
“
Si.Mo.Ne.
” server if any movement is detected:
•
P.0583
: configures the minimum movement (in meters), beyond which the controller sends a
message to “
Si.Mo.Ne.
” server.
•
P.0584
: configures a minimum interval for the issue of position messages to “
Si.Mo.Ne.
”
server (at most the controller sends a message in the configured interval).
➢
If = 0 is set, it sends an event to each motion detection.
➢
If > 0 is set, it sends the motion detect event each time the set time has elapsed after
exceeding the threshold in meters expressed in
P.0583
.
The controller displays the
GNSS
coordinates on page S.04.
The coordinates flash if the
GNSS
module is not able in that
moment to determine the position (therefore the last position
detected is shown). It also shows the
HDOP
(Horizontal
Dilution of Precision) value: it is a precision indicator (the lower
it is, the sharper the position).
Finally, next to the HDOP value, they are indicated in
brackets:
➢
the number of satellites that are "view" by the
GNSS
module (when searching for
coordinates).
➢
the number of satellites used for the "
FIX
" of the coordinates (once the correct position
has been determined).
If the
GNSS
module is not used, it is still possible to manually set the latitude (
P.0581
) and
longitude (
P.0582
) of the generator set to display the position on the map or on the "
Si.Mo.Ne
"
WEB interface (for example in the versions with Ethernet card that communicate with the
"Si.Mo.Ne" system).
Si.Mo.Ne.
” system is a centralized system of data collection: such data are then consultable
through a WEB interface. Controllers can communicate with “
Si.Mo.Ne.
” system both through
Ethernet port and through GPRS/LTE modem. These parameters can be modified on the
controller through the relative programming menu, with the BoardPrg3xx and also through the
web service in the appropriate configuration page of the device:
Parameter
Name
Default
P.0530
Enable to connect and send
“Si.Mo.Ne.” packet
0-No
P.0531
IP address or
“Si.Mo.Ne.” primary server name
P.0532
“Si.Mo.Ne.” primary server port
0
P.0533
IP address or “Si.Mo.Ne.” secondary server name
P.0534
Si.Mo.Ne. secondary server port
0
P.0535
Time for sending data with engine running
900
P.0536
Time for sending data with engine off
3600
P.0537
Time for sending “Keep Alive Network” packet
0
P.0539
Communication events
0000
P.0542
Type of genset voltage
2-DC voltages
S.04 NETWORK |
NAME SCe_HS315link
IP:
10.6.5.55
Lati: +55.70588
Long: +5.8562
HDOP: 0.7(9)
Содержание HS 315
Страница 1: ...File name EAAM058607EN docx Rev 07 Date 25 09 2019 ID Document EAAM0586 Product HS315...
Страница 17: ...Technical Handbook xvii...
Страница 18: ......
Страница 23: ...Technical Handbook 5 Rear view Hall...
Страница 254: ......