12
Technical Handbook
Environmental conditions
Operating temperature
From -25°C to +60°C
Stock temperature
From -30°C to +80°C
Humidity
IEC 60068-2-30
Db Damp Heat Cyclic 20/55°C @ 95% RH 48 Hours
IEC 60068-2-78
Cab Damp Heat steady state 40°C @ 93% RH 48 Hours
Box
Material
ABS + PC
Size
244(L) x 178(H) x 50(P) mm
Hole size
218x159mm
Weight
600g
Protection degree
IP65 with gasket for the front panel
IP20 for the panel interior
Auxiliary source and generator voltages
(AC):
1Vrms
accuracy <0.5% F.S.
Auxiliary source and generator frequencies
(AC):
0.1Hz ±50ppm, 35ppm/C typical
DC Voltages (JG and JH)
50mV
DC Currents
Shunt:
0,1mV
Hall
MIN. 15mA
MAX. 150mA
Current value depends on external transducer.
Powers
Min. 0.1 kW (depends on the current transformers ratio)
Engine speed
1 rpm
Oil pressure
0.1bar (below 10bar)
Coolant temperature
0.1°C
Fuel level
0.1%
PT100
0.1°C
Analogue input JQ
<40mV (for DC source)
<10mV (for generic measure)
Analogue output JR
0.3 mV/bit