Technical Handbook 83
Current menu name, selected menu item and number of menu items are always displayed in
the second line. Menu items (submenus) are displayed in the following lines. The item selected
is displayed in REVERSE. Use the ▲ e ▼ buttons to cyclically scroll through the menu to the
lower and upper index items (i.e. pressing the
▲ allows to directly cycle from the first item to
the last one).
Press the
ENTER
button to access the selected (highlighted) sub-menu. Press the
ESC
button
to leave the menu (back to the previous menu or to the base screen if exiting programming in
the main menu).
The name of the current menu (for
example the menu “1-SYSTEM”) is always shown in the
first line, followed by the numeric ID of the selected item and the number of menu items. The
following lines are used to display single parameters. In detail:
•
The unambiguous parameter code (four decimal digits), followed by the description
in the current language, is shown in the fourth and fifth line.
•
The sixth line shows the variable value, aligned to the right side, between brackets
or
“< >”.
•
For some parameters, on the eighth line, a value is shown, which is in some way
related to the actual parameter value. For example, in the case of the minimum
voltage threshold for the generator (%), the rated value in Volt is shown. Sometimes,
this additional measure can be displayed for showing its absolute value, when the
parameter is a percentage of other values.
Use the ▲ e ▼ buttons to cyclically scroll through the menu to the lower and upper index items
(i.e. pressing the ▲ allows to directly cycle from the first item to the last one and vice versa).
Press the
ENTER
button to enable the parameter modification procedure (see following
paragraph). Press the
ESC
button to leave the menu (back to the previous menu).
You may only modify parameters displayed between square brackets ([ ]). A parameter
between (major/minor) symbols < > cannot be modified. In this case it could be necessary to
set an appropriate password or stop the gen-set.
In case modifying the displayed parameter is allowed, press the
ENTER
button; the square
brackets ([ ]) enclosing the value will blink to signal that the modification is in progress. To
confirm the new value, press again the
ENTER
button; to abort and return to the original value,
press the
ESC
button;
Parameter types are the following:
•
Bits
:
Some parameters are managed with bits. Each bit set to 1 enables a function
and each bit set to 0 disables a function. Each bit is assigned a value. The parameter
must be set as the result of the sum of the values associated to the functions you
require to enable (in hexadecimal mode). 8 bits can be used. The description of these
parameters is shown in a table like the one below:
Bit
Value
Hexadecimal
Description
0
1
0001
Enable function 1
1
2
0002
Enable function 2
2
4
0004
Enable function 3
3
8
0008
Enable function 4
4
16
0010
Enable function 5
5
32
0020
Enable function 6
6
64
0040
Enable function 7
Содержание HS 315
Страница 1: ...File name EAAM058607EN docx Rev 07 Date 25 09 2019 ID Document EAAM0586 Product HS315...
Страница 17: ...Technical Handbook xvii...
Страница 18: ......
Страница 23: ...Technical Handbook 5 Rear view Hall...
Страница 254: ......