Chapter 3 Specifications for each unit
3.1 SEL Unit, Terminal Unit
3-10
ME0392-4C
(3) System status LED
It is a set of LED lamps to display the status of the SEL unit and field network.
LED display specifications
LED name
Color
Status
Content
T RUN
Green
Light ON
Normal internal bus communication
Blinking
Waiting for initialization signal
Orange
Light ON
Bus communication error generated
SYS
Green
Light OFF
Not Ready
Blinking (2Hz)
Updating
Blinking (0.5Hz) Update Complete
Light ON
Ready
Orange
Light OFF
Not Alarm
Light ON
Alarm
Blinking
Control power voltage drop detection
MODE
Green
Light OFF
MANU (manual operation) mode ON
Light ON
AUTO (automatic operation) mode ON
Blinking
System-shutdown level error is present
PWR
Green
Light OFF
Power not Supplied, Startup Error
Light ON
Power on normal condition
STOP
Red
Light OFF
STOP not Input
Light ON
STOP under Input
ENB
Green
Light OFF
In Disable Status
Light ON
Enable status
MODE
PWR
STOP
ENB
T.RUN
SYS
3.1 SEL Unit, Terminal Unit
ME0392-4C
3-11
(4) System operation setting switch
It is a switch to set the system operation mode.
OFF
⇔
ON
Set all off in the normal use.
(Operation may not be performed in the normal condition with any of them set on)
(5) USB connector
It is a connector to be connected to the PC software.
For how to install the driver, refer to [PC software (RSEL) Instruction manual (ME0398)].
Connector type
Mini-B
Model
51387-0530
Manufacturer
Molex
Pin No.
Signal name
Description
5
GND
Power supply ground
4
ID
USB ID (dentification) terminal
3
D+
USB
Differential
transmitted/received data
+
side
2
D-
USB
Differential
transmitted/received data
-
side
1
Vbus
USB Power supply input
Shell
GND
Power supply ground
SYS.SW
1
4
USB
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......