Chapter
11 T
roubleshooting
11.3 Error List
11-5
ME0392-4C
Error
No.
Error name
Content and Cause /
Countermeasure
Me
ssa
ge
205
Target value of total times
of motion exceeded
[Content & Cause]
1) The total times of axis operation has exceeded the times set in Each
Axis Parameter No. 20 “Total travel count threshold”.
[Countermeasure]
1) Consider to have a maintenance work on the actuator.
206
Target travel distance
exceeded
[Content & Cause]
1) The total distance of axis operation has exceeded the distance set in
Each Axis Parameter No. 148 “Total travel distance threshold”.
[Countermeasure]
1) Consider to have a maintenance work on the actuator.
207
Update error
[Content & Cause]
1) Update command was received when in a mode other than Update Mode.
2) The name of the update program file selected in the update mode is
invalid.
3) The update program file is invalid.
4) The system application received an updating target specification command.
5) There is an error in the password received from the updating tool.
6) When updating, a flash-ROM write command was received before a
flash-ROM erase command.
[Countermeasure]
1) Rebooting
2) Update command was received when in a mode other than Update Mode.
2), 3), 6) Select the correct file and have an update again from the beginning.
4) Reboot the power and conduct the update again.
5) Check if the updating tool is applicable.
208
Flash ROM error
[Content & Cause]
1) Data delete in the flash ROM or writing to the flash ROM did not finish
in normal condition due to the causes below:
1. Noise Applied
2. Malfunction of Flash ROM
2) Sum check error in code domain in flash ROM
3) Version information mismatched in code domain in flash ROM
4) Data writing to the flash ROM did not finish in normal condition due to
the causes below:
1. Noise Applied
2. Malfunction of Flash ROM
5) Data delete in the flash ROM did not finish in normal condition due to
the causes below:
1. Noise Applied
2. Malfunction of Flash ROM
6) Data was corrupted in the flash ROM due to the causes below:
1. Noise Applied
2. Malfunction of Flash ROM
[Countermeasure]
1) -1, 4) -1, 5) -1, 6) -1
Take a countermeasure to noise on controller (such as installing ferrite
core)
1) -2, 4) -2, 5) -2, 6) -2
Replace SEL unit
2), 3) Rebooting
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......