Chapter 5 Operation
5.10 ELECYLINDER Operation
5-32
ME0392-4C
[I/O Signal List]
EC Connection Unit
(ON = corresponding bit is “1”, OFF = corresponding bit is “0”)
Signal type
Bit
Signal name
Content
Details
PLC
out
put
Control signal
(4th Axis)
b15
-
Not available
-
b14
RES
Alarm Cancel
[Alarm cancelled with on]
b13
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
b12
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Control signal
(3th Axis)
b11
-
Not available
b10
RES
Alarm Cancel
[Alarm cancelled with on]
b9
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
b8
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Control signal
(2nd Axis)
b7
-
Not available
b6
RES
Alarm Cancel
[Alarm cancelled with on]
b5
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
b4
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Control signal
(1st Axis)
b3
-
Not available
b2
RES
Alarm Cancel
[Alarm cancelled with on]
b1
ST1
Drive Forward
[Drives forward with on (drives forward
after home-return operation when home
return not complete), decelerate and stop
on the way with off]
b0
ST0
Drive Backward
[Drives backward with on (drives
backward after home-return operation
when home return not complete),
decelerate and stop on the way with off]
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......