Chapter
11 T
roubleshooting
11.5 Causes and Countermeasures for ELECYLINDER Alarms
11-89
ME0392-4C
[Alarm group B: Motor abnormality alarm]
Motor abnormality occurred.
No.
Cause
Countermeasure
1
The internal temperature of the motor may be
too high.
Improve the surrounding environment of the
motor so that the ambient temperature is 40 °C
or less.
If the abnormality is resolved upon turning the
power back on after the ambient temperature is
lowered, the internal temperature may have
been excessive.
[Countermeasure examples]
Remove the heat source/turn OFF the heat
source/install a fan/install a temperature
shield/improve thermal conductivity of the
base/install a heat dissipation fin, etc.
2
The ELECYLINDER may be being used under
conditions exceeding the specifications
described in the catalog.
Check the specification values such as payload,
acceleration/deceleration and speed, and adjust
them appropriately.
3
If this alarm recurs after performing the
inspection above and improving the power
supply environment, it is highly likely that the
motor has failed.
Replacement of the motor is required. For some
models, the motor cannot be replaced by the
customer. In that case, please contact IAI.
[Alarm group C: ELECYLINDER control unit abnormality alarm]
ELECYLINDER control unit abnormality occurred.
No.
Cause
Countermeasure
1
The ELECYLINDER control unit is affected by
the noise of a peripheral device and cannot
operate normally.
Shut down the power supply of the peripheral
device and operate only with the
ELECYLINDER, then check to see whether this
alarm persists.
If it does not, there is a possibility that the
ELECYLINDER is affected by the noise from the
peripheral device.
Reconsider the noise countermeasures
(grounding, power line wiring, electrostatic
shielding, etc.) for the peripheral device.
2
If this alarm recurs after performing the
inspection above and improving the power
supply environment, it is highly likely that the
ELECYLINDER control unit has failed.
Replace the controller cover assembly of the
ELECYLINDER.
→
For the replacement method, refer to the
[Instruction manual for each ELECYLINDER].
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......