11.3 Error List
11-55
ME0392-4C
Error
No.
Error name
Content and Cause /
Countermeasure
Co
ld
-st
art
60C
Fieldbus FBRS link error
[Content & Cause]
1) Contact error on fieldbus connection cable
2) Cable breakage on fieldbus connection cable
3) Following data does not match the setting on the PLC side
• I/O Parameter No. 14 “Number of I/O Fieldbus Remote Input Used
Ports”
• I/O Parameter No. 15 “Number of I/O Fieldbus Remote Output Used
Ports”
• I/O Parameters from No. 132 to 135 “I/O Fieldbus Self IP Addresses (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameter from No. 136 to 139 “I/O Fieldbus Subnet Mask (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameters from No. 140 to 143 “I/O Fieldbus Default Gateway (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameter No. 184 “Number of CC-Link IE Remote Register
(Input) Words (RWw)”
• I/O Parameter No. 184 “Number of CC-Link IE Remote Register
(Output) Words (RWr)”
• I/O Parameter No. 226 “I/O1 Fieldbus Node Address”
• I/O Parameter No. 227 “I/O1 Fiedlbus Baud Rate”
• I/O Parameter No. 228 “I/O1 Fieldbus Network Number”
4) Noise
[Countermeasure]
1) Check the connection status of fieldbus connection cable and connect
again
2) Replace fieldbus connection cable
3) Check the following parameters and establish the controller parameter
settings or change the settings on the PLC side.
• I/O Parameter No. 14 “Number of I/O Fieldbus Remote Input Used
Ports”
• I/O Parameter No. 15 “Number of I/O Fieldbus Remote Output Used
Ports”
• I/O Parameters from No. 132 to 135 “I/O Fieldbus Self IP Addresses (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameter from No. 136 to 139 “I/O Fieldbus Subnet Mask (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameters from No. 140 to 143 “I/O Fieldbus Default Gateway (x)”
* x in brackets ( ) represents H, MH, ML or L in the order from smaller
parameter number
• I/O Parameter No. 184 “Number of CC-Link IE Remote Register
(Input) Words (RWw)”
• I/O Parameter No. 184 “Number of CC-Link IE Remote Register
(Output) Words (RWr)”
• I/O Parameter No. 226 “I/O1 Fieldbus Node Address”
• I/O Parameter No. 227 “I/O1 Fieldbus Baud Rate”
• I/O Parameter No. 228 “I/O1 Fieldbus Network Number”
4) Take a countermeasure to noise on fieldbus connection cable (such as
installing ferrite core)
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......