Chapter 6 Field Network, PIO, SIO
6.2
Functional Specifications
6-22
ME0392-4C
Example of Use (1)
The relation between the RSEL I/O port numbers and the PLC addresses when it is automatic
assignment, input 48 points and output 32 points is as shown below. The RSEL I/O port start numbers
should be from No. 0 for input and from No. 300 for output, and one station should be occupied (32 bits
of the remote input and output (RX/RY) and 4 words of the remote register (RWr/RWw)) on the PLC
side.
RSEL side input port No.
PLC side address (OUT)
RSEL side output port No.
PLC side address (IN)
0 to 15
RY0 to RYF
300 to 315
RX0 to RXF
16 to 31
RY10 to RY1F
316 to 331
RX10 to RX1F
32 to 48
RWw0
Not available
RWr0
Not available
RWw1
RWr1
RWw2
RWr2
RWw3
RWr3
* The shaded part is the system domain for CC-Link, thus not available as I/O.
Example of Use (2)
The relation between the RSEL I/O port numbers and the PLC addresses when it is fixed
assignment, input 256 points and output 256 points is as shown below. The RSEL I/O port start
numbers should be from No. 128 for input and from No. 428 for output. Three stations should be
occupied (96 bits of the remote input and output (RX/RY) and 12 words of the remote register
(RWr/RWw)) on the PLC side.
RSEL side input port No.
PLC side address (OUT)
RSEL side output port No.
PLC side address (IN)
128 to 143
RY0 to RYF
428 to 443
RX0 to RXF
144 to 159
RY10 to RY1F
444 to 459
RX10 to RX1F
160 to 175
RY20 to RY2F
460 to 475
RX20 to RX2F
176 to 191
RY30 to RY3F
476 to 491
RX30 to RX3F
192 to 207
RY40 to RY4F
492 to 507
RX40 to RX4F
208 to 223
RY50 to RY5F
508 to 523
RX50 to RX5F
224 to 239
RWw0
524 to 539
RWr0
240 to 255
RWw1
540 to 555
RWr1
256 to 271
RWw2
556 to 571
RWr2
272 to 287
RWw3
572 to 587
RWr3
288 to 295
1000 to 1007
RWw4
588 to 595
4000 to 4007
RWr4
1008 to 1023
RWw5
4008 to 4023
RWr5
1024 to 1039
RWw6
4024 to 4039
RWr6
1040 to 1055
RWw7
4040 to 4055
RWr7
1056 to 1071
RWw8
4056 to 4071
RWr8
1072 to 1087
RWw9
4072 to 4087
RWr9
Not available
RWwA
Not available
RWrA
RWwB
RWrB
* The shaded part is the system domain for CC-Link, thus not available as I/O.
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......