Chapter 10 Parameter
10.2 Parameter List (SEL Unit)
1. I/O parameter
10-18
ME0392-4C
No.
Parameter name
Setting at
Delivery Input range Unit
Remarks
225 I/O controller
Depends on
Controller
Construction
Reference only
0H to
FFFFFFFFH
Bits 0 to 7: Type of Network I/F Module Control 1
(0H: Not mounted,
1H: CC-Link,
2H: DeviceNet,
3H: PROFIBUS-DP,
4 to 5H: Reserved by the system,
6H: EtherCAT,
7H: EtherNet/IP,
8H: Reserved by the system,
9H: PIO,
AH: PROFINET IO,
B to CH: Reserved by the system,
DH: CC-Link IE)
Bits 8 to 31: Reserved by the system
226
I/O1 Fieldbus Node Address
Depends on
Controller
Construction
0 to
99,999,999
Settable Range
•
At CC-Link: 1 to 64
•
At DeviceNet: 0 to 63
•
At PROFIBUS-DP: 0 to 125
•
At EtherCAT: 0 to 65,535
•
At CC-Link IE: 1 to 120
* Setting establishment not necessary for
EtherNet/IP and PROFINET IO
227
I/O1 fieldbus communication
speed
Depends on
Controller
Construction
0 to 9
•
At CC-Link:
(0:156kbps, 1:625kbps, 2:2.5Mbps, 3:5Mbps,
4:10Mbps)
•
At DeviceNet:
(0:125kbps, 1:250kbps, 2:500kbps)
•
At EtherNet/IP:
(0: Auto negotiation
1:10Mbps (Half-Duplex),
2:10Mbps (Full-Duplex),
3:100Mbps (Half-Duplex),
4:100Mbps (Full-Duplex))
* Setting establishment not necessary for
PROFIBUS-DP, EtherCAT, PROFINET IO and
CC-Link IE
228 I/O1 Fieldbus Network Number
Depends on
Controller
Construction
0 to
99,999,999
•
At CC-Link IE: 1 to 239
* Setting not necessary when other than CC-Link IE
229
to
230
(For expansion)
0
231
to
232
Reserved by the system
0
0 to 256
233
Reserved by the system
-1
-1 to 3,999
234
Reserved by the system
-1
-1 to 6,999
235
Reserved by the system
1
0 to 5
236
Reserved by the system
0H
Reference only
0H to
FFFFFFFFH
237
Reserved by the system
0
0 to
99,999,999
238
Reserved by the system
0
0 to 9
239
Reserved by the system
0
0 to
99,999,999
240
to
282
(For expansion)
0
283 Port number assigned to input
function selection 000
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 30, “Input function
selection 000.”
* If a negative value is set, the function will be
assigned to input port No. 0.
284 Port number assigned to input
function selection 001
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 31, “Input function
selection 001.”
* If a negative value is set, the function will be
assigned to input port No. 1.
10.2
Parameter List (SEL Unit)
1. I/O parameter
ME0392-4C
10-19
No.
Parameter name
Setting at
Delivery Input range Unit
Remarks
285 Port number assigned to input
function selection 002
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 32, “Input function
selection 002.”
* If a negative value is set, the function will be
assigned to input port No. 2.
286 Port number assigned to input
function selection 003
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 33, “Input function
selection 003.”
* If a negative value is set, the function will be
assigned to input port No. 3.
287 Port number assigned to input
function selection 004
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 34, “Input function
selection 004.”
* If a negative value is set, the function will be
assigned to input port No. 4.
288 Port number assigned to input
function selection 005
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 35, “Input function
selection 005.”
* If a negative value is set, the function will be
assigned to input port No. 5.
289 Port number assigned to input
function selection 006
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 36, “Input function
selection 006.”
* If a negative value is set, the function will be
assigned to input port No. 6.
290 Port number assigned to input
function selection 007
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 37, “Input function
selection 007.”
* If a negative value is set, the function will be
assigned to input port No. 7.
* If “Program number specified for program start”
has been specified for input function selection
007, specify in this parameter an input port
number whose LSB contains the next higher value
to the LSB of the program number specified for
program start.
(Related information: I/O parameter No. 30, “Input
function selection 000”)
291 Port number assigned to input
function selection 008.
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 38, “Input function
selection 008.”
* If a negative value is set, the function will be
assigned to input port No. 8.
* If “Program number specified for program start”
has been specified for input function selection
008, specify in this parameter an input port
number whose LSB contains the next higher value
to the LSB of the program number specified for
program start.
292 Port number assigned to input
function selection 009
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 39, “Input function
selection 009.”
* If a negative value is set, the function will be
assigned to input port No. 9.
* If “Program number specified for program start”
has been specified for input function selection
009, specify in this parameter an input port
number whose LSB contains the next higher value
to the LSB of the program number specified for
program start.
293 Port number assigned to input
function selection 010
-1
-1 to 3,999
Specify the port number to be assigned to the
function of I/O parameter No. 40, “Input function
selection 010.”
* If a negative value is set, the function will be
assigned to input port No. 10.
* If “Program number specified for program start”
has been specified for input function selection
010, specify in this parameter an input port
number whose LSB contains the next higher value
to the LSB of the program number specified for
program start.
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......