Chapter
11 T
roubleshooting
11.3 Error List
11-31
ME0392-4C
Error
No.
Error name
Content and Cause /
Countermeasure
O
per
at
io
n-
can
cel
lat
ion
429
Error with next step of
SLCT
[Content & Cause]
1) The program step next to SLCT was not either of WHEQ, WHNE,
WHGT, WHGE, WHLT, WHLE, WSEQ, WSNE, OTHE or EDSL
[Countermeasure]
1) Set the program step next to SLCT to either of WHEQ, WHNE, WHGT,
WHGE, WHLT, WHLE, WSEQ, WSNE, OTHE or EDSL
42A
BGPA, EDPA pair end
mismatch error
[Content & Cause]
1) EDPA declared while BGPA not declared
2) BGPA declared without EDPA declared after BGPA declared
[Countermeasure]
1), 2) Check the program and see the treatment to BGPA and EDPA
42B
Stack format initialization
failure
[Content & Cause]
1) Malfunction of controller
[Countermeasure]
1) Replace SEL unit
42C
Expansion condition code
error
[Content & Cause]
1) Error in extension conditional codes
[Countermeasure]
1) Check the extension conditions in the program step that the error
occurred
42D
Input condition CND
insufficient error
[Content & Cause]
1) There was no necessary input conditions even in use of extension
conditions
[Countermeasure]
1) Check the input conditions in the program step that the error occurred
42E
Actuator control
declaration error
[Content & Cause]
1) There is an error in setting in actuator control declaration command
[Countermeasure]
1) Check the setting in the actuator control declaration command in the
program step that the error occurred
42F
Timer setting out of range
[Content & Cause]
1) TIMW Command time setting is out of the range
[Countermeasure]
1) Check the timer setting in the program step that the error occurred
Setting Range: 0.01 to 99 seconds
430
Waiting timeout setting
out of range
[Content & Cause]
1)
WT□□
command timeout setting is out of the range
[Countermeasure]
1) Check the timeout setting in WT
�
�
�
�
Command in the program step that
the error occurred
Setting Range: 0.01 to 99 seconds
431
TSLP command setting
range error
[Content & Cause]
1) A negative value was set in TSLP Command time setting
[Countermeasure]
1) Set a positive value in TSLP Command time setting
11.3 Error List
ME0392-4C
11-32
Error
No.
Error name
Content and Cause /
Countermeasure
O
per
at
io
n-
can
cel
lat
ion
432
DIV command divisor 0
error
[Content & Cause]
1) 0 was indicated to the devisor (Operand 2) in DIV Command
[Countermeasure]
1) Check the devisor (Operand 2) in DIV Command in the program step
that the error occurred and set a value other than 0
433
SQR command range
error
[Content & Cause]
1) There is an error in SQR Command data (Operand 2)
[Countermeasure]
1) Check the data (Operand 2) in SQR Command in the program step that
the error occurred and set up a value more than 0
434
BCD display digits range
error
[Content & Cause]
1) There is an error in the number of digits to display BCD
[Countermeasure]
1) Set the number of digits to display to 1 or more and 8 or less in the
program step that the error occurred
435
No. of 1-shot pulse
outputs used
simultaneously exceeded
the limit
[Content & Cause]
1) The number of BTPN and BTPF timers operating at the same time in
one program has exceeded the upper limit (16)
2) The number of output at the same time in a position output operation
feature (output during delay and pulse output included) has exceeded
the upper limit (16)
[Countermeasure]
1) Have the number of BTPN and BTPF timers operating at the same time
in the program that the error occurred not to exceed the upper limit (16)
2) Check the SEL program or position number that the error occurred and
avoid exceeding the upper limit (16) of the number of output at the
same time in the position output operation feature
436
SEL language PTRQ
command preparation
process error
[Content & Cause]
1) Setting value in PTRQ is out of the range
[Countermeasure]
1) Check if the setting in PTRQ is out of the range in the program step
that the error occurred
437
Sub-routine error
[Content & Cause]
1) There is no definition in the sub-routine to be called
2) Sub-routine is defined in several points in the same sub-routine number
3) Sub-routine number setting is out of range
[Countermeasure]
1) Define a sub-routine to be called
2) Check the program and avoid defining sub-routine in several points in
the same sub-routine number
3) Indicate a sub-routine number in the setting range (1 to 99)
438
Error with the divisor 0
when MOD commanded
[Content & Cause]
1) The divisor was set to 0 in MOD Command
[Countermeasure]
1) Check the divisor in MOD Command in the program step that the error
occurred and set it to a number other than 0
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......