
Chapter 5 Operation
5.10 ELECYLINDER Operation
5-38
ME0392-4C
<Example>
When 256 points are used for both input and output in the field network (such as EtherNet/IP)
and the automatic assignment is selected, the input and output ports should be assigned as
shown below.
●
Input port: 0 to 255
●
Output port: 300 to 555
In there, if the last 16 points in the field network is assigned to an EC connection unit, the setting
should be as shown below.
●
Option board parameters No.2 = “1: I/O control”
●
Option board parameters No.3 = 240
●
Option board parameters No.4 = 540
[2] Control of SEL program
The input and output ports assigned to the EC connection unit should be operated directly in the
SEL program.
In order to stop ELECYLINDER on the way, turn ST0/ST1 Signals off.
ELECYLINDER would not stop with operations described below.
•
HOLD, CANC Command
•
“
Operation Pause Signal
”
in input feature select
•
Pause, program termination or all axes termination in PC software or TB-02
•
03
5.10 ELECYLNDER Operation
ME0392-4C
5-39
5.10.6 Timing for input and output signals
The maximum response time from the control signal gets turned on till it reaches ELECYLINDER
and the status signal from ELECYLINDER returns to PLC when an actuator is operated in a PLC
sequence program can be expressed with formulas shown below.
Also, PLC should be the master station and the gateway unit should be the remote I/O station.
PLC → Max. Response Time of ELECYLINDER : Yt + Tt + Ft
ELECYLINDER → Max. Response Time of PLC : Gt + Tt + Xt
Yt = “Master Stationv
→
Remote I/O Station” Transmission Latency
Xt =
“Remote I/O Station
→
Master Station” Transmission Latency
Tt = Process Time inside SEL Unit
+
Transmission Time (5 ms)
Ft = ELECYLINDER Input Filter (6 to 26
ms)
Gt = RCON
-EC-4
Input Filter (6 to 26
ms)
* Ft or Gt may differ depending on the model of ELECYLINDER to be
connected.
Refer to “an instruction manual of a PLC” installed to “each field network master unit” about the
transmission latencies from the master station to the remote I/O station (Yt) and from the remote
I/O station to the master station
(Xt)
.
【
PLC
→
エレシリンダー】
PLC
制御信号
SEL
ユニット制御信号
RCON-EC
制御信号
エレシリンダー制御信号
Yt
Tt
Ft
(6
~
26ms)
PLC
制御信号
SEL
ユニット制御信号
RCON-EC
制御信号
エレシリンダー制御信号
Xt
Tt
Gt
(6
~
26ms)
【エレシリンダー
→
PLC
】
[PLC
→ ELECYLINDER
]
[ELECYLINDER
→
PLC]
PLC control signal
PLC control signal
SEL unit control signal
SEL unit control signal
RCON-EC control signal
RCON-EC control signal
ELECYLINDER control signal
ELECYLINDER control signal
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......