Chapter 5 Operation
5.10 ELECYLINDER Operation
5-30
ME0392-4C
[2] Control Using SEL Program
[Operation image]
(1) With using the SEL program, input the movement command signals to an EC connection
unit. (Forward or backward)
(2) Input the movement signal from EC connection unit to each unit of ELECYLINDER.
(3) ELECYLINDER units start moving.
(4) A position detection signal gets output from ELECYLINDER. (Forward end or backward
end)
(5) The position detection signal gets output from EC connection unit to PLC.
ELECYLINDER continues its operation while a movement command signal (ST0/ST1) is on, and
a position detection signal (LS0/LS1) turns on after the operation is complete.
If the movement command signal gets turned off before the operation completes, the operation
gets cancelled and an actuator decelerates and stops.
The same even applies to the home return
operation.
EC Connection Unit Cable
or
or
or
or
ELECYLINDER
BTOF 397
Forward command OFF
BTON 396
Backward command ON
WTON 96
Backward end detection waiting
BTOF 396
Backward command OFF
BTON 397
Forward command ON
WTON 97
Forward end detection
waiting
SEL program
…
RSEL
EC Connection Unit
Forward
command
Backward
command
Backward
command
Backward end
detection
Backward end
detection
Forward end
detection
Forward
command
(1)
(2)
(4)
Forward end
detection
(5)
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......