Chapter 9 Special Functions
9.4 Predictive Maintenance Function
9-18
ME0392-4C
[For driver unit]
The driver overload warning (message level error) should be detected when the ratio of the load
assuming the presumed motor raised temperature that could generate the driver overload error
as 100 % (hereinafter described as overload level) has exceeded the value set in the parameter.
By setting a parameter separately, the driver overload warning can be output to a port.
The indication of the ratio above and the output port should be done in the parameters below.
(1) Driver Unit Parameter No. 143 “Overload Warning Loading Level Ratio”
The ratio should be set to detect Error No. 22C “Motor Drive Control Error” assuming the
overload level (driver overload error loading level) to detect Error No. 61A “Overload Error”
(cold start level error) as 100 (%).
The setting range should be “50 to 100 (%)” and if 100 (%) or a number out of the range is
set, the driver overload warning and the driver overload warning output should get invalid.
●
Driver Unit Parameter
No.
Parameter Name Setting at
Delivery
Input
range
Unit
Remarks
143 Overload Warning
Loading Level Ratio
100
50 to 100
% Set in % from Driver overload error loading
level (invalid at 100)
(2) Axis Parameter No. “Driver Overload Warning Output Number”
A port number to conduct the driver overload warning output (break contact) should be set. If
an output port number other than 0 is set in this parameter, the driver overload warning output
activates. When 0 or a number out of the range is set, the driver overload warning output
should get invalid.
●
Axis Parameter
No.
Parameter Name Setting at
Delivery
Input
range
Unit
Remarks
37
Driver Overload
Waring Output
Number
0
0 to 6,999
Physical output port or extension output port
(Output invalid at 0, duplicated indication
invalid)
* Break Contact
* Both (1) and (2) are set invalid at the delivery.
9.4 Predictive Maintenance Function
ME0392-4C
9-19
[In case of EC connection unit (ELECYLINDER)]
●
For ELECYLINDER, it is not in the parameters, but in the maintenance information screen in
the teaching tool to set the ratio. When each setting values are exceeded, there should be
“Maintenance Warning 3” generated and the status LED on ELECYLINDER should flash in
green and red in turns to notify.
●
When the motor temperature rise value falls below the ratio set as “overload warning level”,
“Maintenance warning 3” will be automatically cleared.
●
When “Maintenance warning 3” is output, investigate the cause of the increase in load.
Maintenance such as greasing or reviewing the operating conditions is recommended.
●
Setting it to “100 %” will disable this function.
All of maintenance warning LEDs from 1 to 3 on
ELECYLINDER flash in green and red in turns.
/ alternate blinking
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......