Chapter
11 T
roubleshooting
11.5 Causes and Countermeasures for ELECYLINDER Alarms
11-91
ME0392-4C
[Alarm group E: Supply voltage/power capacity abnormality alarm]
An abnormality occurred in the power supply voltage and capacity supplied to the rear of the
ELECYLINDER.
No.
Cause
Countermeasure
1
The ELECYLINDER may be being used under
conditions exceeding the specifications
described in the catalog.
Check the specification values such as payload,
acceleration/deceleration and speed, and adjust
them appropriately.
2
The power supply voltage has been detected
outside the range of 21.6V to 26.4V.
Inspect with a tester to see whether the power
supply voltage is in the range of 21.6 V to 26.4 V.
If it is out of range, the 24V DC power supply
voltage has insufficient capacity.
Refer to our catalog for the required capacity
and improve the power supply environment.
3
If this alarm recurs after performing the
inspection above and improving the power
supply environment, it is highly likely that the
ELECYLINDER control unit has failed.
Replace the controller cover assembly of the
ELECYLINDER.
→
For the replacement method, refer to the
[Instruction manual for each ELECYLINDER].
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......