Chapter 9 Special Functions
9.2 PSA-24 Communication Monitor
9-8
ME0392-4C
●
How to Connect with PSA-24
When it is necessary to connect PSA-24 and monitor the status data of the power supply via
RSEL, setting of the number of PSA-24 unit to be connected should be established in Other
Parameter No. 61 “Number of Power Supply Units”.
Other Parameters
No.
Parameter name
Initial
setting Input range Unit
Remarks
61
Power Supply Unit Connected
Number of Units
0
0 to 5
0: No connected
1 to 5: Power supply unit connected number of
units
When using the PC teaching software, select “Monitor (M)”
→
“Power Supply Unit Data (P)”
after the parameter setting is done, and the power supply unit data should be displayed.
[Status data]
The status data available for monitoring is as listed below.
Item
Details
Output Voltage
Output voltage AD converted value. As this power source fluctuates the
output voltage, the output voltage monitored value changes from
moment to moment. Note that it is not an error.
Supplement Coil
Voltage
Control power voltage inside power source AD converted value. It
changes in response to the load on output voltage side as it does for
the output voltage, which is not an error.
Peak Hold Voltage
Output voltage AD converted value. Comparison is performed every
time AD conversion is executed and the maximum voltage is saved.
Output Current
Output current AD converted value. It shows the transient value.
Peak Hold Current
Output current peak value. Comparison is performed every time AD
conversion is executed and the maximum current is saved.
Load Ratio
It is the value expressed in percentage for the ratio of output current
integral value and the rated output current used for overload judgment
internally. If this value exceeds 100%, an overload error should be
generated and output voltage will be cut off.
Peak Hold Load Ratio
Comparison is performed every time overload calculation is executed
and the maximum load ratio is saved.
Fan Revolution Speed
It is the value of number of fan revolution calculated by pulse signal
input from the fan.
PCB Temperature
It is the AD converted value of the temperature sensor around the
secondary side output capacitor.
Total Conducting Time
It is the time the values saved in the internal memory regularly were
integrated by conducting time was counted in CPU.
9.2 PSA-24 Communication Monitor
ME0392-4C
9-9
The background color should change depending on the status of the acquired status of the
power supply unit.
Auxiliary winding voltage : Yellowish green when 15V or more and white when 10V or less
Load factor
: Yellowish green when 330W with fan equipped and white when
220W with no fan equipped
Fan rotating speed
: Gray when no fan equipped, white when fan in normal operation,
yellow when in warning and red when error
When it is necessary to output the monitoring information from the I/O, setting should be
established in I/O Parameter No. 851 “Data I/O Output Setting 01 Data Specifications”. Set the
output data type in bit 00 to 03 (PSA-24: 1) and select the output data items in bit 08 to 15.
I/O Parameter
No.
Parameter name
Initial
setting Input range Unit
Remarks
851
Data IO Output Setting 01
Data Type
0H
0H
~
FFFFFFFF
H
-
* Set 0 when output inactivated.
Bits 00-03: Output data type
(0: Output Invalid, 1: Power Supply Status,
2: Axis Status, 3: EC Status (Main application
part V1.09 or later)
Bits 04-07: (Reserved)
Bits 08-15: Output data item
●
Output data type (Bit 00-03)
= “1: Power Supply Status”
(0: Output Voltage, 1: Auxiliary Winding Voltage,
2: Output Current, 3: Peak Hold Current,
4: Load Ratio, 5: Fan Revolution Speed,
6: Internal Temperature (PCB Temperature))
●
Output data type (Bit 00 to 03)
= “2: Axis Status”
(0: Current Position,
1: Current Speed, 2: Alarm Code,
3: Axis Operation Status, 4: Motor Indicated
Current (Percentage to Rated),
5: Motor Indicated Current [mA],
6: Position Difference, 7: Overload Level,
8: Motor Feedback Current (Percentage to Rated),
9: Motor Feedback Current [mA])
Bits 16-19: Resolution
(0: 1000, 1: 100, 2: 10, 3: 1,
4: 1/10 (0.1), 5: 1/100 (0.01), 6: 1/1000 (0.001))
Bits 20-23: (Reserved)
Bits 24-27: Byte Order
(0: Big Endian,
1: Middle Endian 1 (PDP Endian)
2: Middle Endian 2
3: Little Endian)
Bits 28-31: Data Size
(0: 1byte
1: 2byte (1word)
2: 4byte (2word))
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......