Chapter 6 Field Network, PIO, SIO
6.3 Parameter Configuration
6-84
ME0392-4C
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
132 I/O Fieldbus
Own IP address (H)
192
Optional
* Setting of “0” and “127” is prohibited.
133 I/O Fieldbus
Own IP address (MH)
168
Optional
134 I/O Fieldbus
Own IP address (ML)
0
Optional
135 I/O Fieldbus
Own IP address (L)
1
Optional
* Setting of “0” and “255” is prohibited.
136 I/O Fieldbus
Subnet mask (H)
255
Optional
137 I/O Fieldbus
Subnet mask (MH)
255
Optional
138 I/O Fieldbus
Subnet mask (ML)
255
Optional
139 I/O Fieldbus
Subnet mask (L)
0
Optional
140 I/O Fieldbus
Default gateway (H)
0
Optional
141 I/O Fieldbus
Default gateway (MH)
0
Optional
142 I/O Fieldbus
Default gateway (ML)
0
Optional
143 I/O Fieldbus
Default gateway (L)
0
Optional
186
Number of Connected option
unit
0
3
unit The number of ports used for input and output
should be number of connected units × 16 for each.
187
Option unit fix-allocated input
port start No.
-1
0
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set)
188
Option unit fix-allocated
output port start No.
-1
300
300 + (Multiple of 8) (300 to 599)
4,000 + (Multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set)
189 PIO Unit / PIO/SIO Unit Error
Monitor
1
1
0: Not monitored
1: Monitored
2: Monitored (24V I/O power supply related errors
not monitored)
3: Monitored (only 24V I/O power supply related
errors monitored)
4: Monitored (24V I/O power supply related errors
output as message level)
* Some exceptions apply
190 Option Unit Attribute 1
C800200H Optional
Bits 0 to 3: PIO unit output port data select in TF
connection error (0: Clear, 1: Hold)
Bits 4 to 7: PIO unit input port data select in TF
connection error (0: Clear, 1: Hold)
Bits 8 to 15: TF communication link error check timer
value (10 ms)
Bits 20 to 31: Link timeout value in TF
communication initialization (100 ms)
225 I/O controller
7H
7H
Bits 0-7: Type of Network I/F Module Control 1
(0H
:
Not mounted,
1H
:
CC-Link,
2H
:
DeviceNet,
3H
:
PROFIBUS-DP,
6H
:
EtherCAT,
7H
:
EtherNet/IP,
9H
:
PIO,
AH
:
PROFINET IO,
DH
:
CC-Link IE)
227 I/O1 Fieldbus communication
speed
0
Optional
0: Autonegotiation, 1: 10Mbps (Half-Duplex),
2: 10Mbps (Full-Duplex), 3: 100Mbps (Half-Duplex),
4: 100Mbps (Full-Duplex)
6.3 Parameter Configuration
ME0392-4C
6-85
●
Example of Use (2)
It is the setting when using 192 points each of input and output for EtherNet/IP and 48 points
each of input and output for PIO in a row from the top of the input and output ports (from No.
0 and from No. 300).
In this case, three units of PIO units (16 points x 3 units = 48 points) should be used, and the
input and output ports should be from No. 192 and from No. 492.
No.
Parameter Name
Setting at
Delivery
Set
Value
Unit
Remarks
1
I/O port assignment type
1
1
0: Fixed assignment
1: Automatic assignment
* Priority of I/O port assignment at automatic
assignment
(I/O1
→
PIO unit
•
PIO/SIO unit)
14
Number of Ports Used for
I/O1 Fieldbus Remote Input
0
192
Multiple of 8
15
Number of Ports Used for
I/O1 Fieldbus Remote Output
0
192
Multiple of 8
16
I/O1 fix-allocated input port
start No.
-1
-1
0 + (Multiple of 8) (0 to 299)
1,000 + (Multiple of 8) (1,000 to 3,999)
(Invalid if a negative value is set.)
17
I/O1 fix-allocated output port
start No.
-1
-1
300 + (multiple of 8) (300 to 599)
4,000 + (multiple of 8) (4,000 to 6,999)
(Invalid if a negative value is set.)
18
I/O1 error monitor
1
1
0: Do not monitor
1: Monitor
* Some exceptions apply.
20
Input filtering periods
2
2
ms
Input signal is recognized when the status is
held for twice the period set by this parameter.
* Valid only for PIO, PIO unit /
PIO/SIO unit
120 Network attribute 1
641001H
Optional
Bits4-11: I/O1 Fieldbus link error
confirmation timer value (10 ms)
Bits28-31: Input Port Data Select in I/O1 Fieldbus
Link Error (0: Clear, 1: Hold)
121 Network attribute 2
C80000H
Optional
Bits 16-27: Link timeout value in Fieldbus
initialization (100 ms)
130 I/O Fieldbus
Own MAC address (H)
0H
MAC
address
display
Only lower two bytes are valid.
131 I/O Fieldbus
Own MAC address (L)
0H
MAC
address
display
Input port No.0 to 191
Output port No.300 to 491
Input port No.192 to 239
Output port No.492 to 539
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......