Chapter 4 Unit connection / In
stallation and Wiring
4.4
Wiring Method
4-22
ME0392-4C
[Installation of Noise Filter and Surge Protector on DC Power Supply for Motor Drive]
For the wires to be connected to the power connector, use the following applicable wires.
Caution
Leak current may vary depending on the motor capacity, cable length and ambient
temperature.
Therefore, it is required to measure leak current at the point of the leakage breaker
installed when leakage protection is to be conducted.
A clear purpose is necessary when selecting a leakage breaker such as to protect from
fire or protection of personnel. For leakage breaker, use a high frequency applicable type
(for inverter).
Ground
Class D grounding:
(
Formerly Class-III grounding
:
Grounding resistance at 100
Ω
or less
)
Surge Protector
R
・
A
・
V-781BWZ-2A
(manufactured by Okaya Electric Industries)
Connector model :
MSTB2.5/6-STF-5.08
L1
L2
Leakage Breaker
X
X
Circuit Breaker
Noise Filter
NF2010A-UP
(manufactured by Okaya Electric Industries)
or
NAC-20-472 (manufactured by Cosel)
DC Power Supply for
Motor Drive
(Model : PSA-200-*)
4.4
Wiring Method
ME0392-4C
4-23
[2] Connectivity of Status Output Connector on DC Power Supply for Motor Drive
It should output the status of a DC power supply for motor drive. The output should be linked
to LEDs for PWR, MP and ALM.
Refer below for how to attach the status output connector.
Connector
Pin
No.
Signal
name
Description
Remarks
1
*ALM-
Alarm Contact Output
Photocoupler Insulation Open
Collector Output
2
*ALM+
3
MP-
Motor Power Supply
Contact Output
4
MP+
5
PWR-
Control Power Supply
Contact Output
6
PWR+
Compatible wire diameter
Item
Specifications
Compatible wire
AWG24 to 16
Max. Cable length
10 m
Strip length
10.0 mm
* Use cables with their rated temperature on the isolation sheath at 60°C or higher.
DC Power Supply for Motor Drive
(Model : PSA-200-*)
Tighten up
with slotted
screwdriver
Status Output Connector
(Model : DFMC1.5/3-STF-3.5
)
Screwdriver
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......