Chapter 10 Parameter
10.2 Parameter List (SEL Unit)
1. I/O parameter
10-14
ME0392-4C
No.
Parameter name
Setting at
Delivery Input range Unit
Remarks
125 Network attribute6
31E32H
0H to
FFFFFFFFH
Bits 0 to 7: System Reservation
Bits 8 to 15: System Reservation
Bits 16 to 23: Increment of “PC/TP reconnection
delay at software reset” when
EtherNet is used [s]
126 Network attribute7
7D007D0H
0H to
FFFFFFFFH
Reserved by the system
127 Network attribute8
5050214H
0H to
FFFFFFFFH
EtherNet TCP/IP message communication attribute
Bits 0 to 7: CONNECT_TIMEOUT
(Change is prohibited)
(Setting of “0” is prohibited) [s]
Bits 8 to 15: Connection retry interval
(IAI protocol B/TCP) [s]
Bits 16 to 23: Send timeout value [s]
Bits 24 to 31: IAI protocol B-SIO non-communication
check timer setting [s]
(IAI protocol B/TCP connection trigger)
128 Network attribute9
10000H
0H to
FFFFFFFFH
EtherNet TCP/IP message communication attribute
Bits 0 to 15: SEL server open timeout value [s]
(No timeout check when “0” is set)
129 Network attribute10
0H
0H to
FFFFFFFFH
EtherNet operation requirement
Bits 0 to 3: System Reservation
Bits 4 to 7: TCP/IP message communication
(0: Not in use, 1: Use)
Bits 8 to 31: Reserved (Operation requirement)
130 I/O FIELDBUS
Own MAC address (H)
0H
Reference only
(HEX)
Only lower two bytes are valid.
131 I/O FIELDBUS
Own MAC address (L)
0H
Reference only
(HEX)
132 I/O FIELDBUS
Own IP address (H)
192
1 to 255
*Setting of “0” and “127” is prohibited.
* Setting establishment not necessary for
PROFINET IO
133 I/O FIELDBUS
Own IP address (MH)
168
0 to 255
* Setting establishment not necessary for
PROFINET IO
134 I/O FIELDBUS
Own IP address (ML)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
135 I/O FIELDBUS
Own IP address (L)
1
1 to 254
*Setting of “0” and “255” is prohibited.
* Setting establishment not necessary for
PROFINET IO
136 I/O FIELDBUS
Subnet mask (H)
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
137 I/O FIELDBUS
Subnet mask (MH)
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
138 I/O FIELDBUS
Subnet mask (ML)
255
0 to 255
* Setting establishment not necessary for
PROFINET IO
139 I/O FIELDBUS
Subnet mask (L)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
140 I/O FIELDBUS
Default gateway (H)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
141 I/O FIELDBUS
Default gateway (MH)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
142 I/O FIELDBUS
Default gateway (ML)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
143 I/O FIELDBUS
Default gateway (L)
0
0 to 255
* Setting establishment not necessary for
PROFINET IO
144 IAI protocol B/TCP: Own port
number (MANU mode)
64511
1025 to
65,535
* Important note: Always set a unique number for
each port number.
(Duplication of port numbers is permitted only in
the IAI protocol B/TCP MANU/AUTO modes.)
145 Channel 31 opened to user
(TCP/IP): Own port number
64512
1025 to
65,535
* Important note: Always set a unique number for
each port number.
(Duplication of port numbers is permitted only in
the IAI protocol B/TCP MANU/AUTO modes.)
146 Channel 32 opened to user
(TCP/IP): Own port number
64513
1025 to
65,535
* Important note: Always set a unique number for
each port number.
(Duplication of port numbers is permitted only in
the IAI protocol B/TCP MANU/AUTO modes.)
147 Channel 33 opened to user
(TCP/IP): Own port number
64514
1025 to
65,535
* Important note: Always set a unique number for
each port number.
(Duplication of port numbers is permitted only in
the IAI protocol B/TCP MANU/AUTO modes.)
Содержание R-unit RSEL
Страница 2: ......
Страница 5: ...ME0392 4C 2 Quick Start Guide Japanese Only ...
Страница 32: ...Actuator Coordinate System Intro 18 ME0392 4C 2 Slider type 3 Table type 0 0 0 0 ...
Страница 50: ...Chapter 1 RSEL System 1 4 Installation 1 13 ME0392 4C ...
Страница 82: ...Chapter 2 System Configuration and Power Specifications 2 6 Drive Source Cutoff 2 30 ME0392 4C ...
Страница 244: ...Chapter 4 Unit connection Installation and Wiring 4 5 PIO Circuit 4 32 ME0392 4C ...
Страница 249: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 37 Appearance ...
Страница 251: ...Chapter 4 Unit connection Installation and Wiring 4 7 Brake Box Option ME0392 4C 4 39 Appearance ...
Страница 316: ...Chapter 5 Operation 5 10 ELECYLINDER Operation 5 52 ME0392 4C ...
Страница 438: ...Chapter 6 Field Network PIO SIO 6 5 Example of Connectivity Setting 6 120 ME0392 4C ...
Страница 472: ...Chapter 7 6 axis Cartesian Robot 7 2 Caution When Using Orthogonal Coordinate System Features 7 33 ME0392 4C ...
Страница 530: ...Chapter 9 Special Functions 9 6 RSEL Serial Communication Multiple Channel Applicable Features 9 38 ME0392 4C ...
Страница 532: ...10 6 Servo Gain Adjustment 10 90 10 7 Parameter Configuration Advanced Use 10 93 ...
Страница 638: ...Chapter 10 Parameter 10 7 Parameter Configuration Advanced Use 10 106 ME0392 4C ...
Страница 838: ...Chapter 14 Warranty 14 Warranty 14 3 ME0392 4C ...
Страница 843: ......
Страница 844: ......