Proline Cubemass 300 Modbus RS485
Description of device parameters
Hauser
107
Active level (1351–1 to n)
Response time (1354–1 to n)
Terminal no.
Navigation
Expert → Input → Status input 1 to n → Terminal no. (1358–1 to n)
Description
Displays the terminal numbers used by the status input module.
User interface
• Not used
• 24-25 (I/O 2)
• 22-23 (I/O 3)
Additional information
"Not used" option
The status input module does not use any terminal numbers.
Assign stat.inp.
Navigation
Expert → Input → Status input 1 to n → Assign stat.inp. (1352–1 to n)
Description
Use this function to select the function for the status input.
Selection
• Off
• Reset totaliz. 1
• Reset totaliz. 2
• Reset totaliz. 3
• Reset all tot.
• Flow override
Factory setting
Off
Additional information
Selection
• Off
The status input is switched off.
• Reset totaliz. 1…3
The individual totalizers are reset.
• Reset all tot.
All totalizers are reset.
• Flow override
The Flow override (→ 78) is activated.
Note on the Flow override (→ 78):
• The Flow override (→ 78) is enabled as long as the level is at the status input
(continuous signal).
• All other assignments react to a change in level (pulse) at the status input.