Proline Cubemass 300 Modbus RS485
Description of device parameters
Hauser
169
Subnet mask
Navigation
Expert → Communication → Web server → Subnet mask (7211)
Description
Displays the subnet mask.
User entry
4 octet: 0 to 255 (in the particular octet)
Factory setting
255.255.255.0
Default gateway
Navigation
Expert → Communication → Web server → Default gateway (7210)
Description
Displays the default gateway.
User entry
4 octet: 0 to 255 (in the particular octet)
Factory setting
0.0.0.0
Webserver funct.
Navigation
Expert → Communication → Web server → Webserver funct. (7222)
Description
Use this function to switch the Web server on and off.
Selection
• Off
• On
Factory setting
On
Additional information
Description
Once disabled, the Webserver funct. can only be re-enabled via or the operating tool
FieldCare.
Selection
Option
Description
Off
• The web server is completely disabled.
• Port 80 is locked.
On
• The complete functionality of the web server is available.
• JavaScript is used.
• The password is transferred in an encrypted state.
• Any change to the password is also transferred in an encrypted state.
Содержание Proline Cubemass 300