Proline Cubemass 300 Modbus RS485
Modbus RS485 Register Information
Hauser
261
"User-spec. units" submenu
Navigation: Expert → Sensor → System units → User-spec. units
Parameter
Register
Data type
Access
Selection / User entry / User interface
→
Mass text (0560)
String
Read / Write
Max. 10 characters such as letters,
numbers or special characters (@, %, /)
Mass factor (0561)
Float
Read / Write
Signed floating-point number
Mass offset (0562)
Float
Read / Write
Signed floating-point number
Volume text (0567)
String
Read / Write
Max. 10 characters such as letters,
numbers or special characters (@, %, /)
Volume factor (0568)
Float
Read / Write
Signed floating-point number
Corr. vol. text (0592)
String
Read / Write
Max. 10 characters such as letters,
numbers or special characters (@, %, /)
Cor.vol. factor (0590)
Float
Read / Write
Signed floating-point number
Corr vol. offset (0602)
Float
Read / Write
Signed floating-point number
Volume offset (0569)
Float
Read / Write
Signed floating-point number
Density text (0570)
String
Read / Write
Max. 10 characters such as letters,
numbers or special characters (@, %, /)
Density factor (0572)
Float
Read / Write
Signed floating-point number
Density offset (0571)
Float
Read / Write
Signed floating-point number
Pressure text (0581)
String
Read / Write
Max. 10 characters such as letters,
numbers or special characters (@, %, /)
Pressure factor (0579)
Float
Read / Write
Signed floating-point number
Pressure offset (0580)
Float
Read / Write
Signed floating-point number
"Process param." submenu
Navigation: Expert → Sensor → Process param.
Parameter
Register
Data type
Access
Selection / User entry / User interface
→
Flow damping (1802)
5510 to 5511
Float
Read / Write
0 to 100.0 s
Density damping (1803)
5508 to 5509
Float
Read / Write
0 to 999.9 s
Temp. damping (1822)
5127 to 5128
Float
Read / Write
0 to 999.9 s
Flow override (1839)
5503
Integer
Read / Write
0 = Off
1 = On
"Low flow cut off" submenu
Navigation: Expert → Sensor → Process param. → Low flow cut off
Parameter
Register
Data type
Access
Selection / User entry / User interface
→
Assign variable (1837)
5101
Integer
Read / Write
0 = Off
1 = Mass flow
2 = Volume flow
3 = Correct.vol.flow
On value (1805)
5138 to 5139
Float
Read / Write
Positive floating-point number
Off value (1804)
5104 to 5105
Float
Read / Write
0 to 100.0 %
Pres. shock sup. (1806)
5140 to 5141
Float
Read / Write
0 to 100 s