Proline Cubemass 300 Modbus RS485
Modbus RS485 Register Information
Hauser
277
"Totalizer 1 to n" submenu
Navigation: Expert → Application → Totalizer 1 to n
Parameter
Register
Data type
Access
Selection / User entry / User interface
→
Assign variable (0914–1 to n)
1: 2601
2: 2801
3: 3001
Integer
Read / Write
0 = Off
1 = Mass flow
2 = Volume flow
3 = Correct.vol.flow
74 = Target mass flow
75 = Carrier mass fl.
78 = Carrier vol. fl.
79 = Carr.corr.vol.fl
86 = GSV flow
87 = GSVa
88 = Oil mass flow
89 = Water mass flow
90 = NSV flow
91 = NSVa
92 = S&W volume flow
94 = Oil corr.vol.fl.
95 = Water corr.v.fl.
96 = Targ.corr.vol.fl
97 = Target vol. flow
99 = Oil volume flow
102 = Water vol. flow
Unit totalizer 1 to n (0915–1 to n)
1: 4604
2: 4605
3: 4606
Integer
Read / Write
0 = cm³
1 = dm³
2 = m³
3 = ml
4 = l
5 = hl
6 = Ml Mega
8 = af
9 = ft³
10 = fl oz (us)
11 = gal (us)
12 = Mgal (us)
13 = bbl (us;liq.)
14 = bbl (us;beer)
15 = bbl (us;oil)
16 = bbl (us;tank)
17 = gal (imp)
18 = Mgal (imp)
19 = bbl (imp;beer)
20 = bbl (imp;oil)
22 = kgal (us)
50 = g
51 = kg
52 = t
53 = oz
54 = lb
55 = STon
100 = Nl
101 = Nm³
102 = Sm³
103 = Sft³
104 = Sl
105 = Sgal (us)
106 = Sbbl (us;liq.)
107 = Sgal (imp)
251 = None
Operation mode (0908–1 to n)
1: 2605
2: 2805
3: 3005
Integer
Read / Write
0 = Net flow total
1 = Forward total
2 = Reverse total