Description of device parameters
Proline Cubemass 300 Modbus RS485
180
Hauser
Operation mode
Navigation
Expert → Application → Totalizer 1 to n → Operation mode (0908–1 to n)
Prerequisite
One of the following options is selected in the
Assign variable
the
Totalizer 1 to n
submenu:
• Volume flow
• Mass flow
• Correct.vol.flow
• Target mass flow
• Carrier mass fl.
Description
Use this function to select how the totalizer summates the flow.
Selection
• Net flow total
• Forward total
• Reverse total
Factory setting
Net flow total
Additional information
Selection
• Net flow total
Flow values in the forward and reverse flow direction are totalized and balanced against
one another. Net flow is registered in the flow direction.
• Forward total
Only the flow in the forward flow direction is totalized.
• Reverse total
Only the flow in the reverse flow direction is totalized (= reverse flow quantity).
Control Tot. 1 to n
Navigation
Expert → Application → Totalizer 1 to n → Control Tot. 1 to n (0912–1 to n)
Prerequisite
One of the following options is selected in the
Assign variable
the
Totalizer 1 to n
submenu:
• Volume flow
• Mass flow
• Correct.vol.flow
• Target mass flow
• Carrier mass fl.
Description
Use this function to select the control of totalizer value 1-3.
Selection
• Totalize
• Reset + hold
• hold
• Reset + totalize
• totalize
• Hold
*
Visibility depends on order options or device settings