Proline Cubemass 300 Modbus RS485
Description of device parameters
Hauser
219
Assign proc.var.
Navigation
Expert → Diagnostics → Simulation → Assign proc.var. (1810)
Description
Use this function to select a process variable for the simulation process that is activated.
The display alternates between the measured value and a diagnostic message of the
"Function check" category (C) while simulation is in progress.
Selection
• Off
• Mass flow
• Volume flow
• Correct.vol.flow
• Target vol. flow
• Carrier vol. fl.
• Targ.corr.vol.fl
• Carr.corr.vol.fl
• Density
• Ref.density
• Ref.dens.altern.
• GSV flow
• GSVa
• NSV flow
• NSVa
• S&W volume flow
• Water cut
• Oil density
• Water density
• Oil mass flow
• Water mass flow
• Oil volume flow
• Water vol. flow
• Oil corr.vol.fl.
• Water corr.v.fl.
• Density average
• Temp. average
• Temperature
• Concentration
• Target mass flow
• Carrier mass fl.
Factory setting
Off
Additional information
Description
The simulation value of the process variable selected is defined in the
Proc. var. value
*
Visibility depends on order options or device settings