Description of device parameters
Proline Cubemass 300 Modbus RS485
142
Hauser
Assign diag. beh
Navigation
Expert → Output → PFS output 1 to n → Assign diag. beh (0482–1 to n)
Prerequisite
• In the
Operating mode
Switch
option is selected.
• In the
Switch out funct
Diag. behavior
option is selected.
Description
Use this function to select the diagnostic event category that is displayed for the switch
output.
Selection
• Alarm
• Alarm or warning
• Warning
Factory setting
Alarm
Additional information
Description
If no diagnostic event is pending, the switch output is closed and conductive.
Selection
• Alarm
The switch output signals only diagnostic events in the alarm category.
• Alarm or warning
The switch output signals diagnostic events in the alarm and warning category.
• Warning
The switch output signals only diagnostic events in the warning category.
Assign limit
Navigation
Expert → Output → PFS output 1 to n → Assign limit (0483–1 to n)
Prerequisite
• The
Switch
option is selected in the
Operating mode
parameter (→ 126).
• The
Limit
option is selected in the
Switch out funct
Description
Use this function to select a process variable for the limit function.
Selection
• Mass flow
• Volume flow
• Correct.vol.flow
• Target mass flow
• Carrier mass fl.
• Target vol. flow
• Carrier vol. fl.
• Targ.corr.vol.fl
• Carr.corr.vol.fl
• Density
• Ref.density
• Ref.dens.altern.
• GSV flow
*
Visibility depends on order options or device settings