Description of device parameters
Proline Cubemass 300 Modbus RS485
78
Hauser
Additional information
Description
The damping is performed by a PT1 element
.
User entry
• Value = 0: no damping
• Value > 0: damping is increased
Damping is switched off if
0
is entered (factory setting).
Temp. damping
Navigation
Expert → Sensor → Process param. → Temp. damping (1822)
Description
Use this function to enter a time constant for the damping (PT1 element) of the
temperature measured value.
User entry
0 to 999.9 s
Factory setting
0 s
Additional information
Description
The damping is performed by a PT1 element
.
User entry
• Value = 0: no damping
• Value > 0: damping is increased
Damping is switched off if
0
is entered (factory setting).
Flow override
Navigation
Expert → Sensor → Process param. → Flow override (1839)
Description
Use this function to select whether to interrupt the evaluation of measured values. This is
useful for the cleaning processes of a pipeline, for example.
Selection
• Off
• On
Factory setting
Off
3)
Proportional behavior with first-order lag
4)
Proportional behavior with first-order lag
Содержание Proline Cubemass 300