Troubleshooting
ASDA-B3
13-44
13
AL215 Write parameters: read-only
Trigger condition
and cause
Condition: when you use the PR procedure to write the parameter, the parameter
is read-only.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method
and corrective action
The specified parameter is read-only.
How to clear the
alarm?
DI.ARST
AL217
Write parameters: write-protected when Servo On
Trigger condition
and cause
Condition: when you use the PR procedure to write the parameter, the parameter
is write-protected when the servo drive is on or the parameter value exceeds the
range.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method
and corrective action
Write the parameter when the servo drive is off and make sure the parameter
value is within the range.
How to clear the
alarm?
Modify the PR command and the parameter.
AL219 Write parameters: parameter cannot be written
Trigger condition
and cause
Condition: this parameter is write-protected.
Cause: the parameter write-protected function is enabled.
Checking method
and corrective action
Check if the parameter and data array protection function (P5.097) is enabled.
How to clear the
alarm?
Disable the parameter and data array protection function or reset the parameters.
AL231 Monitoring item of Type [8] PR is out of range
Trigger condition
and cause
Condition: the code of the monitoring item for Type [8] PR command
is out of range.
Cause: the code of the monitoring item is out of range.
Checking method
and corrective action
Write parameter using PR procedure: when the code of the monitoring item
exceeds the range, check the code range for the monitoring item.
How to clear the
alarm?
DI.ARST
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...