Parameters ASDA-B3
8-78
8
P2.045
Notch filter frequency (3)
Address: 025AH
025BH
Default:
1000
Control mode: All
Unit:
Hz
Setting range: 50 - 5000
Format:
DEC
Data size:
16-bit
Settings:
The third setting for resonance frequency. This function is disabled if P2.046 is 0.
P2.046
Notch filter attenuation level (3)
Address: 025CH
025DH
Default:
0
Control mode: All
Unit:
-dB
Setting range: 0 - 40 (0: disable this function)
Format:
DEC
Data size:
16-bit
Settings:
The third Notch filter attenuation level. A value of 5 indicates -5 dB.
P2.047
Auto resonance suppression mode
Address: 025EH
025FH
Default:
0x0001
Control mode: All
Unit:
-
Setting range: 0x0000 - 0x01F2
Format:
HEX
Data size:
16-bit
Settings:
Y
Z
U
X
X
Auto resonance suppression function
Z
Fixed resonance suppression parameter
Y
Fixed resonance suppression parameter
U
Reserved
X: auto resonance suppression function
0: disable auto resonance suppression. After the function is disabled, the existing resonance
suppression parameter values do not change.
1: auto resonance suppression mode 1; when the servo determines it is stable*
2
, the servo stores
the resonance suppression points to EEPROM (non-volatile memory for parameters) and
disables the auto resonance suppression function (X = 0). Before the servo is stable,
(1)
If you cycle power on the servo drive, the found resonance suppression points are lost
and will not be saved. The servo searches for the resonance suppression points again.
(2)
If you switch the setting of X from 1 to 0, the known resonance suppression points will be
stored to EEPROM.
(3)
If you keep the setting of X as 1, the known resonance suppression points will not be
cleared, but they are not written to EEPROM yet. They are written to EEPROM when the
servo determines it is stable.
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...