Specifications
ASDA-B3
A-4
A
Item
Specification
Protection function
Overcurrent, Overvoltage, Undervoltage, Overheat, Regeneration error,
Overload, Excessive speed deviation, Excessive position deviation,
Encoder error, Calibration error, Emergency stop, Forward / reverse
limit error, Serial communication error, RST leak phase, Serial
communication timeout, Short-circuit protection for terminals U, V,
and W.
Communication interface
RS-485 / USB / CANopen / DMCNET / EtherCAT
En
vi
ro
n
m
en
t
Installation site
Indoors (avoid direct sunlight), no corrosive vapor (avoid fumes,
flammable gases, and dust)
Altitude
Below 2,000 m above sea level
Atmospheric pressure
86 kPa - 106 kPa
Operating temperature
0˚C - 55˚C (32˚F - 131˚F) (If the operating temperature is above 45˚C
(113˚F), forced cooling is required)
Storage temperature
-20˚C to +65˚C (14˚F to 176˚F)
Humidity
Under 0 - 90% RH (non-condensing)
Vibrating
9.80665 m/s
2
(1 G), less than 20 Hz, 5.88 m/s
2
(0.6 G), 20 to 50 Hz
IP rating
IP20
Power system
TN system
*3*4
Approvals
IEC/EN/UL/TUV
*5
61800-5-1
Note:
1.
Within the rated load, the speed ratio is: the minimum speed (smooth operation) / rated speed.
2.
Within the rated speed, the speed calibration ratio is:
(rotational speed with no load - rotational speed with full load) / rated speed.
3.
TN system: the neutral point of the power system connects directly to the ground. The exposed metal
components connect to the ground through the protective ground conductor.
4.
Use a single-phase three-wire power system for the single-phase power model.
5.
Only B3A series model is TUV certified.
6.
CE Certificate:
https://downloadcenter.deltaww.com/downloadCenterCounter.aspx?DID=21744&DocPath=1&hl=zh-
TW
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...