Motion Control
ASDA-B3
7-44
7
Event triggering
For the event triggering method, you use Event trigger commands 1 - 4 to execute the specified
PR path. There are two types of Event triggering: rising-edge trigger and falling-edge trigger.
The range of PR path numbers that you can specify is from 51 - 63 (see the example in Figure
7.1.5.3). Before using the event triggering for PR commands, you must define the DI functions,
which are [0x39] Event trigger command 1, [0x3A] Event trigger command 2, [0x3B] Event
trigger command 3, and [0x3C] Event trigger command 4 (see Table 8.1). You can use the DI/O
setting screen in ASDA-Soft to set these functions, as shown in Figure 7.1.5.4.
DI 2: [0x39]
Event trigger command 1
PR#51
PR#52
PR path No. to be executed
DI 3: [0x3A]
Event trigger command 2
PR#62
PR#63
51
62
52
63
Figure 7.1.5.3 Example of event triggering timing diagram
Figure 7.1.5.4 DI/O setting screen in ASDA-Soft
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...