Operation Mode
ASDA-B3
6-28
6
6.4.3 Smooth Torque command
Refer to Chapter 8 for detailed descriptions of the relevant parameter.
Parameter
Function
P1.007
Torque command smoothing constant (low-pass filter)
Target
torque
P1.007
t
6.4.4 Scaling of the analog command
The Torque command is controlled by the analog voltage difference between T_REF and GND.
Adjust the torque slope and its range with P1.041.
For example:
1.
If you set P1.041 to 100 and the external input voltage is 10V, the Torque command is 100%
of the rated torque.
2.
If you set P1.041 to 300 and the external input voltage is 10V, the Torque command is 300%
of the rated torque.
300%
100%
-300%
-100%
The slope is set by P1.041.
Analog voltage
input (V)
10
5
-10
-5
Torque command
Refer to Chapter 8 for detailed descriptions of the relevant parameter.
Parameter
Function
P1.041
Maximum output for analog Torque command
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...