Parameters ASDA-B3
8-120
8
P5.053
Delay time after position reached (Number #13)
Address: 056AH
056BH
Default:
4500
Control mode: PR
Unit:
ms
Setting range: 0 to 32767
Format:
DEC
Data size:
16-bit
Settings:
The fourteenth delay time of PR mode.
P5.054
Delay time after position reached (Number #14)
Address: 056CH
056DH
Default:
5000
Control mode: PR
Unit:
ms
Setting range: 0 to 32767
Format:
DEC
Data size:
16-bit
Settings:
The fifteenth delay time of PR mode.
P5.055
Delay time after position reached (Number #15)
Address: 056EH
056FH
Default:
5500
Control mode: PR
Unit:
ms
Setting range: 0 to 32767
Format:
DEC
Data size:
16-bit
Settings:
The sixteenth delay time of PR mode.
P5.056 -
P5.059
Reserved
P5.060
Target speed setting #0
Address: 0578H
0579H
Operation
interface:
Panel / software
Communication
Control mode: PR
Default:
20.0
200
Data size:
32-bit
Unit:
1 rpm
0.1 rpm
-
-
Setting range: 0.0 to 6000.0
0 to 60000
-
-
Format:
DEC
DEC
-
-
Example:
15 = 15 rpm
150 = 15 rpm
-
-
Settings:
First target speed of PR mode.
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...