Motion Control
ASDA-B3
7-38
7
Speed command
You can use the Speed command in any PR paths (PR#1 - PR#99). It is marked as “Speed”.
See Figure 7.1.4.3.
PR#1 (I)
Speed
DLY = [0] 0 ms
100 rpm
Acc = [0] 6.67 ms
Dec = [0] 6.67 ms
(1)
(2)
(3)
(4)
(5)
Figure 7.1.4.3 Speed command display
(1)
Command execution type (property): a Speed command can interrupt (INS) the previous
PR path. If the Interrupt function is enabled, it displays (I); if not, no information is
displayed.
(2)
Delay time (DLY): determined by the shared PR parameters. It is defined by a command
from the controller; the servo drive starts counting the delay time once it reaches the target
speed.
(3)
Target speed: the set target speed.
(4)
Acceleration time (ACC): determined by the shared PR parameters; length of time to reach
the target speed from stopped.
(5)
Deceleration time (DEC): determined by the shared PR parameters; length of time to
decelerate from target speed to stopped.
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...