ASDA-B3 Troubleshooting
13-43
13
AL209 Parameter number of Type [8] PR is out of range
Trigger condition
and cause
Condition: parameter number of Type [8] PR command is out of range.
Cause: the number of Type [8] PR command source exceeds the range.
Checking method
and corrective action
Write parameter using PR procedure: when the parameter number of command
source exceeds the range, check the set range of the number for the written
parameters.
How to clear the
alarm?
DI.ARST
AL207
Parameter group of Type [8] PR is out of range
Trigger condition
and cause
Condition: parameter group of Type [8] PR command is out of range.
Cause: the group of Type [8] PR command source exceeds the range.
Checking method
and corrective action
Write parameter using PR procedure: when the parameter group of command
source exceeds the range, check the group setting of the written parameters.
How to clear the
alarm?
DI.ARST
AL211 Parameter format setting of Type [8] PR is in error
Trigger condition
and cause
Condition: parameter format setting of Type [8] PR command is in error.
Cause:
1.
Incorrect parameter format.
2.
The ASDA-Soft software version and the firmware version do not match.
Checking method
and corrective action
1.
Check if the parameter format is correct.
2.
Check if you are using the latest version of the ASDA-Soft software.
If you took the corrective actions but the issue persists, contact the local distributor
or technician.
How to clear the
alarm?
DI.ARST
AL213 Parameter setting of Type [8] PR is in error
Trigger condition
and cause
Condition: when you use Type [8] PR command to write the parameter,
the parameter value is incorrect.
Cause: an error occurs when you write the parameter with Type [8] PR command.
Checking method
and corrective action
Make sure the parameter value is within the correct range.
How to clear the
alarm?
DI.ARST
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...