background image

Falk

®

 CT-Series Gear Drives • Operation and Maintenance

Sizes 2160 thru 2400

 

(Page 1 of  7)

Rexnord 

GR3-014

3001 W. Canal St., Milwaukee, WI 53208-4200 

January 2017

Telephone: 414-937-4359   Fax: 414-937-4359   www.rexnord.com 

NEW

How to Use this Manual

This manual provides detailed instructions on installation 

and maintenance of  Falk CT-Series gear drive. Use the 

table of  contents below to locate required information.
CAREFULLY FOLLOW THE INSTRUCTIONS IN THIS 

MANUAL FOR OPTIMUM PERFORMANCE AND 

TROUBLE-FREE SERVICE OF YOUR FALK GEAR DRIVE.

TABLE OF CONTENTS

1. Introduction .....................................................................1
2. General Notes and Safety Instructions............................1
3. Transport and Storage.....................................................2
4. Installation .......................................................................3
5. Shaft Connections ...........................................................5
6. Lubrication .......................................................................5
7. Preparation For Test Run .................................................5
8. Maintenance ....................................................................6

1. INTRODUCTION

Credit for long service and dependable operation of  a 

gear drive is often given to the engineers who designed it, 

or the craftsmen who constructed it, or the sales engineer 

who recommended the type and size. Ultimate credit 

belongs to the mechanic on the job who worked to make 

the foundation rigid and level, who accurately aligned the 

shafts and carefully installed the accessories, and who 

made sure that the drive received regular lubrication. The 

details of  this important job are the subject of  this manual.

NAMEPLATE

 — Operate Falk gear drives only at power, 

speed and ratio shown on the nameplate. Before changing 

any one of  these, submit complete nameplate data and 

new application conditions to Factory for correct oil level, 

parts, and application approval.

LUBRICATION

 — Lubrication of  gears and bearings is 

entirely self-contained by splash. In general oil grade to be 

used is ISO-VG 320. Oil thrower on input shaft produces 

positive splash which in turn, ensures continuous 

circulation of  oil to top bearings through channels.

WARNING: 

Consult applicable local and national safety 

codes for proper guarding of  rotating members. Lock out 

power source and remove all external loads from drive 

before servicing drive or accessories.

WARRANTY 

— Rexnord Industries, LLC (the ”Company”) 

warrants that Falk V-Class

 gear drives (I) conform to 

Company’s published specifications, and (II) are free from 

defects of  material for two years from the date of  shipment.
Company does not warrant any non-Company branded 

products or components (manufacturer’s warranty applies) 

or any defects in damage to, or failure of products caused 

by: (I) dynamic vibrations imposed by the drive system in 

which such products are installed unless the nature of such 

vibrations has been defined and accepted in writing by 

Company as a condition of operation; (II) failure to provide 

suitable installation environment; (III) use for purposes other 

than those for which designed, or other abuse or misuse; 

(IV) unauthorized attachments, modifications or disassembly, 

or (V) mishandling during shipping.

QUALIFIED PERSONNEL

 — The product or system 

to which these instructions relate may be handled only 

by persons qualified for the work concerned and in 

accordance with the instructions relating to the work 

concerned, particularly the safety and warning notes 

contained in those instructions. Qualified personnel must 

be specially trained and have the experience necessary to 

recognize risks associated with these products or systems 

and to avoid possible hazards.

2. GENERAL NOTES AND SAFETY 

INSTRUCTIONS

The proper working of  a gear unit not only depends on 

the good design, the use of  good material and good 

workmanship but also on careful installation, proper 

lubrication and proper working conditions. Hence, it is 

of  utmost importance to see that the installation of  the 

gear box is one according to the instructions given in this 

manual to ensure proper working of  the gear box and to 

ensure a long and trouble free service.
This manual should be kept with the person in-charge 

who handles the installation & operation. They should 

thoroughly study and understand the instructions 

given in this manual. Precisely following of  this manual 

will give trouble free working of  the Gear unit. In the 

interest of  future development, we reserve the right to 

introduce modifications to the individual subassemblies & 

accessories, which, while retaining the essential features, 

can be regarded as desirable to increase their efficiency, 

reliability and safety.

2.1  INSTRUCTIONS FOR LONG STORAGE OF GEAR 

UNITS

Following instructions for the long time storage of  the 

gear units is of  extreme importance as violation of  

which can lead to the premature failure.
Long time storage of  a gear unit can be due to:

2.1.1

  Unit is not in action, however, installed in the place

2.1.2

  Unit is kept in store and waiting for its use.

              OR

2.1.3

  The unit is installed but not in action:

When the gear unit is installed in the system 

but is out of  action, a quantity of  oil must be 

added to exceed maximum level by 30 mm to 

50 mm. Special attentions should be given to 

the condition of  the oil. Old oil, which may form 

a deposit or be acidic, should be removed. 

The gears should be turned slowly by hand at 

intervals, in order to ensure the oil is distributed 

over all parts in contact. Wherever grease nipples 

are provided, add grease through grease nipples.

2.1.4

  The unit is to be stored for a long time:

When the unit is to be stored for a long time, it 

should be run for 5 minutes after filling with rust 

protective oil. The level of  the oil should be about 

30 mm to 50 mm higher than the normal oil level. 

All the parts having been thoroughly coated with 

oil, the protective fluid can be drained and kept 

for other similar operations.
The inspection covers and the drain plugs should 

be completely sealed. On starting up the speed 

reducer, no special precaution need be taken 

Содержание Falk CT Series

Страница 1: ...thorized attachments modifications or disassembly or V mishandling during shipping QUALIFIED PERSONNEL The product or system to which these instructions relate may be handled only by persons qualified for the work concerned and in accordance with the instructions relating to the work concerned particularly the safety and warning notes contained in those instructions Qualified personnel must be spe...

Страница 2: ...gear unit other appropriate measures must be taken This work must always be done by specialist electricians Removed safety equipment must be re installed prior to starting up Notices attached to the gear unit e g rating plate direction arrows etc must always be observed They must be kept free from dirt and paint at all times Missing plates must be replaced Screws which have been damaged during ass...

Страница 3: ...l internals rotating parts all accessible areas Also rotate input shaft in reverse direction to apply VCI 412 on all internals bearings The anticorrosion oil VCI 412 will fully dissolve during putting into operation provided the operating oil in accordance with the lubricants chart see chapter 6 is used 3 3 3 Exterior preservation The exterior preservation of blank parts is carried out independent...

Страница 4: ...ation bolts to the specified torque if necessary use stops to prevent displacement Align the gear unit exactly with the input and output units Record alignment dimensions 4 2 1 Foundation The gear unit must be mounted on leveled foundation using the correct size and type of foundation bolts The foundation must have sufficient load carrying capacity The foundation must be cast in the proportion lik...

Страница 5: ...p for 2 to 5 minutes with the gear drive not running For all drives start the gear drive and allow it to run without load for several minutes to fill system components Verify that the pump is circulating oil properly then shut down drive Recheck oil level and add oil if necessary When everything is satisfactory the drive is ready for operation 7 3 OIL LEVEL MONITORING SYSTEM This monitoring is des...

Страница 6: ...en removed before filling with fresh oil For oil renewal period refer to Table 1 based on the operating temperature Place a suitable container under the oil draining point of the gear unit housing Unscrew the breather plug including reducing screw at the housing top Unscrew the screw plug or the open oil drain cock and drain the oil into the collecting container Drain the oil from the oil supply s...

Страница 7: ...r which the gear unit is operated Only average periods can therefore be stated here These refer to A daily operating time of 24 h An input drive speed of 1500 1 min Maximum oil temperature of 90 C applies to mineral oil 100 C applies to synthetic oil The operator must ensure that the intervals stated in Table 2 are adhered to Under different operating conditions the periods indicated above must be...