S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
2-719
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SYSTEMHEALTH Messages
Error Message
SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_FAILED: Compact Flash firmware CRC
checksum on module [dec] is corrupted.
Explanation
Compact flash firmware has been corrupted.
Recommended Action
Replace the compact flash on this module.
Error Message
SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_INIT_ERRORS: Compact Flash firmware
CRC checksum procedure encountered an error during initialization on module [dec],
reason:([chars]).
Explanation
Compact flash CRC checksum initializations failed.
Recommended Action
Check the compact flash on the board and any relevant system
(mis)configurations.
Error Message
SYSTEMHEALTH-2-OHMS_SUP_CF_REFLASH_FAILED: Compact Flash firmware
refresh procedure failed, replace the compact flash on module [dec]. Reason [dec]
Explanation
Compact flash firmware has been corrupted is corrupted.
Recommended Action
Replace the compact flash on this module.
Error Message
SYSTEMHEALTH-2-OHMS_SWITCH_RELOAD_REQ: Switch reload request due to
errors found [chars] test.
Explanation
The system Health Switch Reload Request.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-2-OHMS_SWITCHOVER_REQ: Supervisor switch over being
requested due to errors found [chars] test.
Explanation
The system Health Switch Over Request.
Recommended Action
No action is required.
Error Message
SYSTEMHEALTH-2-OHMS_TCAM_PARITY_FAILED: TCAM test failed for module
[dec].
Explanation
TCAM test failed for module as uncorrectable parity errors were detected.
Recommended Action
Please schedule a downtime and replace the module.