Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
U6RIB Messages
Error Message
U6RIB-3-RNH_LOOP_ERROR Format: Number of prefixes forming rnh loop
exceeds %d\n Flagging route %s/%d from client \%s\ with nh %s, rnh %s/%d\n as
causing rnh loop
Explanation
U6RIB detected a loop between routes installed in the RIB. Check the message to see
which client caused the loop, and take appropriate ation.
Parameters: Max RNH Loop, Prefix, Prefix Length, Client, Next-hop, Prefix, Prefix Length ...
Recommended Action
Requires operator to intervene.
Error Message
U6RIB-3-RPM_LIB_ERROR Format: %s %d
Explanation
An RPM library function returned an error.
Parameters: Function, RPM Error Code ...
Recommended Action
No action is required.
Error Message
U6RIB-3-SDWRAP_LIB_ERROR Format: %s %s
Explanation
A SDWrap library function returned an error.
Parameters: Function, SDWrap Error Code ...
Recommended Action
No action is required.
Error Message
U6RIB-3-SEND_TO_ERROR Format: Send to u6rib failed: %s
Explanation
The calling process was unable to send a message to U6RIB.
Recommended Action
Use the 'restart' command to restart the feature and clear this problem.
Error Message
U6RIB-3-STRUCT_ERROR Format: Structural error: %s, client \%s\, table
id 0x%08x.
Explanation
A severe data structural error was encountered. The system may run into more errors
because of this problem.
Parameters: Problem, Client, Table id ...
Recommended Action
Use the 'system switchover' command to switch over to the standby supervisor.
If no standby is present, or the standby is not ready, use the 'reload' command to reload the system.
The state of the standby can be checked using the 'show system redundancy ha status' command.
Error Message
U6RIB-3-TABLE_CREATE_ERROR Format: Failed to create table info for
VRF %s for client \%s\
Explanation
U6RIB could not create its table data structure for the VRF being created. There may
be further errors that indicate the failure in more detail. The shown VRF should be reconfigured in
the system. i.e. in global configuration, 'no vrf context <vrf-name>'
Parameters: VRF, Client ...
Recommended Action
Requires operator to intervene.